Skip to main content
Schneider Electric A9N19304

Schneider Electric A9N19304 DPN Vigi RCBO, Type A, 10 A, 10

MPN A9N19304
Obsolete

Schneider Electric Acti9 DPN Vigi, RCBO, 1P+N, Type A, 10 A, 10 mA, C-curve, 6 kA, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19304 specifications
ParameterValue
Control typeToggle
Product typeType A
Trip unit typeThermal-magnetic
Main product or component typeEarth leakage circuit breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009
ColorWhite
Electrical life cycles20000 cycles conforming to IEC 61009
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9N19304 is an Acti9 DPN Vigi residual current circuit breaker with overcurrent protection (RCBO) in a 1P+N format — it combines a thermal-magnetic MCB and a voltage-independent earth leakage module in one 4-module wide (9 mm per pitch) DIN-rail unit. The 10 A rated current (In) at 30 °C and C-curve magnetic trip (5 to 10 x In) mean it's sized for general-purpose socket circuits and small lighting loads where moderate inrush from capacitive or motor-start loads is expected. The 10 mA earth leakage sensitivity (Type A) detects sinusoidal AC and pulsating DC residual currents, which covers most modern electronics and variable-speed drive leakage profiles.

The toggle provides local ON/OFF indication and a contact position indicator. Pollution degree 3 and tropicalisation class 2 per EN 61009 mean it's rated for environments with conductive pollution and high humidity (95 % at 55 °C) — suitable for installation in non-conditioned enclosures. Operating altitude is rated to 2000 m without derating.

The voltage-independent residual current tripping technology means the earth leakage protection operates even if the line voltage is lost — a key safety feature for fault detection on a dead circuit. Electrical and mechanical durability are both rated at 20,000 cycles per IEC 61009.

MPN