Skip to main content
Schneider Electric A9N19532

Schneider Electric A9N19532 Acti9 DPN Vigi 10A C-Curve RCBO,

MPN A9N19532
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, A9N19532, 1P+N, 10 A, C-curve, 30 mA earth leakage, 4500 A breaking capacity, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19532 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity4500 A Icn at 220...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max70 °C
Temp storage min-30 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-30...70 °C
Pollution degree3

All specifications

A9N19532 additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9N19532 is an Acti9 DPN Vigi residual-current circuit breaker with overcurrent protection (RCBO) — a single-module (36 mm wide) device combining a 10 A thermal-magnetic MCB with a 30 mA earth-leakage trip in one 1P+N package. The C-curve (magnetic trip 5–10 x In) handles moderate inrush from lighting or small motor loads without nuisance trips, while the integrated 30 mA residual-current element provides personal protection against earth faults.

Rated current In = 10 A, so it protects a final subcircuit drawing up to 10 A continuous — typical for lighting banks, socket outlets, or small appliances. Breaking capacity Icn = 4500 A at 220–240 V AC, 50/60 Hz, per EN/IEC 61009-2-1. If your site's available fault current exceeds 4.5 kA, you need a higher-rated upstream breaker or a current-limiting device to coordinate. Earth-leakage sensitivity is fixed at 30 mA — the standard threshold for personal protection against indirect contact. The device trips on both overcurrent (thermal-magnetic) and residual current, so it replaces two separate units (MCB + RCCB) in one DIN-rail slot. IP20 on the device body, IP40 inside the modular enclosure — suitable for dry indoor panels, not washdown environments.

Tropicalisation level 2 per IEC 60068-1 indicates the device withstands damp heat conditions typical of non-air-conditioned electrical rooms. The manufacturer provides CE declaration of conformity and, for EU markets, the UKCA marking. RoHS and REACH compliance documentation is available from Schneider Electric's product support pages — the paperwork is clean for cross-border shipments.

MPN
A9N19532