Schneider Electric A9N19631 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19631 Acti9 DPN Vigi RCBO, 6 A, Type A

MPNA9N19631
Active

Schneider Electric Acti9 DPN Vigi RCBO, A9N19631, 1P+N, 6 A rated, C-curve, Type A-SI Super Immunised earth leakage at 30 mA, 6 kA Icn at 230 V AC, thermal-magnetic trip, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N19631 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19631 — Electrical Ratings
ParameterValue
Rated current (In)6 A at 30 °C
Rated operational voltage (Ue)230 V AC
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19631 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19631 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19631 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19631 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

The Type A-SI (Super Immunised) designation means this RCBO is designed to resist nuisance tripping from high-frequency leakage currents generated by modern electronic loads — switched-mode power supplies, VFDs, UPS gear — that can falsely trigger standard Type A or AC RCDs. For industrial panels with higher prospective fault current, verify the upstream device limits the let-through to within 6 kA. Thermal-magnetic trip technology covers both overload (thermal bimetal, slow response) and short-circuit (magnetic solenoid, instantaneous above 5–10 × In). The C-curve is the most common general-purpose characteristic for mixed resistive and inductive loads in distribution — it holds through motor inrush better than a B-curve, while still tripping fast enough on a hard fault.

Panel integration

Snaps onto standard DIN rail. The 1P+N format occupies 4 × 9 mm pitches, leaving the neutral switched and protected alongside the phase.

Frequently asked questions

What does Type A-SI (Super Immunised) mean on this RCBO?

Type A-SI is a super-immunised earth-leakage detection characteristic that resists nuisance tripping from high-frequency leakage currents generated by switched-mode power supplies, VFDs, and other modern electronics, while still detecting sinusoidal AC and pulsating DC fault currents to ground.

What is the breaking capacity of A9N19631?

The rated breaking capacity is 6000 A Icn at 230 V AC, conforming to EN 61009.