Specifications

A9N19632 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19632 — Electrical Ratings
ParameterValue
Rated current (In)10 A at 30 °C
Rated operational voltage (Ue)230 V AC
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19632 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19632 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19632 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19632 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

It carries a 10 A rated current (C-curve thermal-magnetic trip) and 30 mA earth-leakage sensitivity, with a 6 kA breaking capacity at 230 V AC per EN 61009. The Type A-SI (Super Immunised) designation means the residual-current detection is immune to nuisance tripping from high-frequency harmonics or pulsed DC waveforms — common on variable-speed drives, LED lighting, and switched-mode power supplies. That makes this unit a fit for mixed-load final circuits where standard Type A or AC RCDs would false-trip.

The 10 A rating at 30 °C sets the continuous load limit for the protected circuit — sized for lighting, small appliance, or general-purpose socket-outlet groups. The 30 mA sensitivity meets the touch-protection threshold for socket circuits in most residential and commercial codes.

Operating altitude to 2000 m.

Frequently asked questions

What is the Type A-SI (Super Immunised) rating on this RCBO?

The Type A-SI (Super Immunised) designation means the residual-current circuit is designed to resist nuisance tripping from high-frequency harmonics and pulsed DC waveforms — typical on VFD, LED, and SMPS loads.

What standards does the A9N19632 comply with?

It complies with EN/IEC 61009-1 and EN/IEC 61009-2-1, covering combined overcurrent and residual-current circuit breakers for household and similar installations.

Where can I buy the A9N19632?

The A9N19632 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.