Skip to main content
Schneider Electric A9N19633 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19633 Acti9 DPN Vigi RCBO, 13 A, 30 mA

MPNA9N19633
Obsolete

Schneider Electric Acti9, DPN Vigi RCBO, Type A-SI (Super Immunised), 1P+N, 13 A, C-curve, 30 mA earth leakage, 6000 A Icn.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N19633 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19633 — Electrical Ratings
ParameterValue
Rated current (In)13 A at 30 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19633 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19633 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19633 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19633 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1 EN/IEC 61009-1

Product details

What the A9N19633 Is and Why It Matters

It integrates a 13 A thermal-magnetic circuit breaker (C-curve, 5...10 x In magnetic trip) with a 30 mA residual current device, Type A-SI (Super Immunised). The Super Immunised designation means the RCD element is designed to resist nuisance tripping from high-frequency harmonics or pulsed DC waveforms common on modern electronic loads — switched-mode power supplies, variable-speed drives, and LED drivers — without compromising personnel protection. This is the key differentiator from a standard Type A RCBO.

Rated 13 A at 30 °C, this RCBO protects a single outgoing circuit — typically lighting, general-purpose sockets, or small control loads. The 30 mA earth-leakage sensitivity provides personnel protection (shock) and fire protection for the circuit.

Mounts on DIN rail and occupies 4 x 9 mm pitch modules — a compact 36 mm footprint for a 1P+N RCBO. Neutral is on the left. The toggle control provides local ON/OFF indication. Rated for ambient storage from -40 to 60 °C and operates at altitudes up to 2000 m.

Frequently asked questions

What does Type A-SI (Super Immunised) mean on this RCBO?

Type A-SI (Super Immunised) means the residual current device is designed to resist nuisance tripping from high-frequency leakage currents and pulsed DC waveforms generated by modern electronic loads like VFDs, SMPS, and LED drivers, while still providing personnel protection against sinusoidal AC and pulsating DC fault currents.

What is the breaking capacity of the A9N19633?

The breaking capacity is 6000 A Icn at 230 V AC, certified to EN 61009.

Where can I buy the A9N19633 and how is it quoted?

The A9N19633 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN