Schneider Electric A9N19635 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19635 DPN Vigi RCBO, 20 A, 30 mA, Type

MPNA9N19635
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, Type A-SI (Super Immunised), 1P+N, 20 A, 30 mA, Curve C, 6 kA Icn at 230 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N19635 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19635 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 30 °C
Rated operational voltage (Ue)230 V AC
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19635 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19635 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19635 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19635 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

The Type A-SI (Super Immunised) designation means the residual-current detection is filtered to ignore high-frequency leakage currents that would nuisance-trip a standard Type A device. This matters on circuits feeding variable-speed drives, UPS systems, or switch-mode power supplies where normal operating leakage contains harmonics and high-frequency components.

Integration notes

Terminals accept up to 10 mm² flexible or 16 mm² rigid cable — tunnel-type, so strip length and ferrule selection follow standard practice for RCBOs. The toggle control provides local ON/OFF indication and a contact position indicator for visual confirmation of state. Rated for 20000 electrical cycles and 20000 mechanical cycles per IEC 61009, which covers the duty cycle of a distribution outgoer in a typical panel. Environmental limits: storage from -40 to 60 °C, operating altitude up to 2000 m, and 95 % relative humidity at 55 °C. Tropicalisation class 2 per EN 61009 and pollution degree 3 mean it is rated for environments with conductive pollution or occasional condensation — typical of industrial enclosures not fully climate-controlled.

Frequently asked questions

What does Type A-SI (Super Immunised) mean on this RCBO?

Type A-SI (Super Immunised) means the residual-current detector is filtered to ignore high-frequency leakage currents that would nuisance-trip a standard Type A device. It is specified for circuits with VFDs, UPS systems, or SMPS where normal operating leakage contains harmonics.

What is the breaking capacity of the A9N19635?

The breaking capacity is 6000 A Icn at 230 V AC per EN 61009, suitable for residential and light commercial distribution boards.

What compliance standards does the A9N19635 meet?

The A9N19635 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. It carries overvoltage category III, pollution degree 3, and tropicalisation class 2 per those standards.