Schneider Electric A9N19656 DPN Vigi, Type AC RCBO, 20 A B-C

MPN A9N19656
Obsolete

Schneider Electric Acti9 DPN Vigi, Type AC earth leakage circuit breaker, 1P+N, 20 A, B-curve, 30 mA sensitivity, 6 kA Icn at 230 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19656 specifications
ParameterValue
Control typeToggle
Product typeType AC
Trip unit typeThermal-magnetic
Main product or component typeEarth leakage circuit breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009
ColorWhite
Electrical life cycles20000 cycles conforming to IEC 61009
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9N19656 is an Acti9 DPN Vigi earth leakage circuit breaker — a combined MCB and RCD in a single 1P+N module. It carries a Type AC earth-leakage detection circuit, rated at 30 mA sensitivity, with instantaneous tripping. The overcurrent side is a B-curve thermal-magnetic breaker rated at 20 A, with a 6 kA breaking capacity at 230 V AC.

Type AC detection means this unit responds to sinusoidal AC earth-leakage currents only. It is the standard choice for circuits feeding resistive loads, lighting, and general socket outlets where no electronic loads generate pulsed or DC fault currents. The B-curve (magnetic trip between 3 and 5 times In, so 60 to 100 A) suits predominantly resistive or lighting circuits with low inrush; it is not intended for motor or transformer loads where a C or D curve would be needed to avoid nuisance tripping on startup.

The unit is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1, the harmonized standards for residual current operated circuit breakers with integral overcurrent protection. Tropicalisation class 2 per EN 61009 means it withstands 95% relative humidity at 55 °C. Operating altitude is rated to 2000 m without derating.