Schneider Electric A9N19665 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19665 DPN N Vigi RCBO, 16A C Curve 30m

MPNA9N19665
Active

Schneider Electric Acti9 DPN N Vigi RCBO, Type AC, 1P+N, 16 A, C curve, 30 mA earth leakage, 6 kA Icn at 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N19665 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19665 — Electrical Ratings
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)230 V AC
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19665 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19665 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19665 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19665 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1 EN/IEC 61009-1

Product details

It packs a thermal-magnetic trip for overload and short-circuit (C curve, magnetic trip 5–10 x In) plus voltage-independent residual current detection at 30 mA Type AC. That 30 mA sensitivity covers the standard personnel-protection threshold per EN/IEC 61009, so it's the go-to for socket-outlet circuits, lighting, and general-purpose final subcircuits where you need both fault-current and earth-leakage protection in one DIN-rail slot.

The 30 mA residual sensitivity is instantaneous (no intentional delay), so it clears a ground fault in the time the standard requires — no coordination with downstream RCDs unless you add selective types upstream.

Neutral is on the left, line on the right — fixed polarity, so verify busbar orientation before racking in. The toggle gives clear ON/OFF indication and a local contact-position flag.

Frequently asked questions

What is A9N19665's listed type (Type AC) on this component line?

The residual current detection is Type AC, meaning it trips on sinusoidal AC earth-leakage currents only. For pulsed DC or smooth DC fault currents, a Type A or Type B device would be required.

What is A9N19665's listed range (Acti9) on this component line?

It belongs to the Schneider Electric Acti9 range, which is the modular DIN-rail protection and control family for residential and commercial distribution boards.

How do I get current pricing and availability for A9N19665?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What compliance documentation does this brand provide for A9N19665?

The device is certified to EN/IEC 61009-2-1 and EN/IEC 61009-1, with tropicalisation and pollution degree 3 per EN 61009. The manufacturer provides a declaration of conformity; specific RoHS/REACH/UL documentation should be requested at quote time.

MPN
A9N19665