Schneider Electric A9N19671

Schneider Electric A9N19671 DPN Vigi 6A Type AC RCBO, B Curv

MPN A9N19671
Obsolete

Schneider Electric Acti9 DPN Vigi, earth leakage circuit breaker, Type AC, 1P+N, 6 A, B curve, 300 mA sensitivity, 6 kA Icn, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19671 specifications
ParameterValue
Control typeToggle
Product typeType AC
Trip unit typeThermal-magnetic
Main product or component typeEarth leakage circuit breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009
ColorWhite
Electrical life cycles20000 cycles conforming to IEC 61009
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The A9N19671: Type AC detection means this RCBO trips on sinusoidal AC earth-leakage currents only — the standard choice for general-purpose distribution circuits feeding resistive, inductive, or electronic loads without DC components or pulsed waveforms. It is not rated for Type A or Type F applications where smoothed DC or mixed-frequency leakage may be present. The 300 mA sensitivity is a fire-protection threshold, not a personnel-protection level (30 mA is typical for that). It suits outgoing sub-distribution circuits feeding fixed equipment where nuisance tripping from cable capacitance or surge suppressors would be a problem. B curve (3...5 x In) means the instantaneous magnetic trip operates between 18 A and 30 A for this 6 A unit. Rated insulation voltage 400 V AC and overvoltage category III confirm it is suitable for fixed-installation distribution boards downstream of the main incoming supply, not for final sub-circuits at the equipment level (category II).

Neutral is on the left, phase on the right, which is the standard Acti9 DPN arrangement. Ambient operating temperature range is -25...60 °C (storage -40...60 °C), with 95% RH at 55 °C. Electrical and mechanical durability are both rated at 20,000 cycles per IEC 61009 — sufficient for distribution switching but not for frequent load-break duty like a contactor. The toggle actuator provides local ON/OFF indication.

MPN
A9N19671