Schneider Electric A9N19673

Schneider Electric A9N19673 DPN N Vigi RCBO, 10 A, Type AC,

MPN A9N19673
Obsolete

Schneider Electric Acti9 DPN N Vigi, RCBO, 1P+N, 10 A, B-curve, 300 mA Type AC, 6 kA, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19673 specifications
ParameterValue
Control typeToggle
Product typeType AC
Trip unit typeThermal-magnetic
Main product or component typeEarth leakage circuit breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009
ColorWhite
Electrical life cycles20000 cycles conforming to IEC 61009
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9N19673 is a DPN N Vigi RCBO from the Acti9 range — a combined overcurrent and earth-leakage circuit breaker in a single 1P+N module. It protects a single pole plus neutral, with the neutral switched and on the left side of the unit. The 10 A rated current (at 30 °C) and B-curve (magnetic trip 3–5 × In) suit it for general-purpose distribution circuits feeding resistive and light inductive loads like lighting or socket outlets. The 300 mA Type AC earth-leakage sensitivity catches sinusoidal AC fault currents; it is the standard choice for basic shock protection in residential and commercial final circuits where no DC-sensitive or pulsed-current detection is required.

That is the standard domestic and light commercial fault level in most European installations; for industrial panels with higher prospective short-circuit currents you would step to a 10 kA or 15 kA device. The limitation class 3 (per EN 61009) means let-through energy is low enough to protect downstream wiring and loads without cascading — a useful detail for panel builders coordinating with upstream MCCBs.

That is the standard 1P+N modular footprint, so it fits directly into any Acti9 or Multi9 distribution board without re-spacing. The toggle gives clear ON/OFF indication, and the contact position indicator confirms the state even when the toggle is hidden behind a sealed cover.