Schneider Electric A9N19675 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19675 DPN Vigi 16A B Curve 30mA RCBO,

MPNA9N19675
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, 1P+N, 16 A, B curve, 300 mA Type AC residual, 6 kA breaking capacity, thermal-magnetic trip, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N19675 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19675 — Electrical Ratings
ParameterValue
Rated current (In)16 A at 30 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19675 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19675 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19675 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19675 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

What this RCBO does for a distribution board

The A9N19675 is a single-module (4 x 9 mm pitches) DPN Vigi residual-current circuit breaker from the Acti9 range, combining overcurrent and earth-leakage protection in one 1P+N package. Its 16 A rated current at 30 °C and B curve (magnetic trip at 3 to 5 times In) suit it for general-purpose socket-outlet and lighting circuits where inrush is low and nuisance tripping on cable charging is a risk.

Snaps onto DIN rail. Tunnel-type terminals accept one 10 mm² flexible or 16 mm² rigid conductor. Neutral is on the left (fixed position). The toggle provides ON/OFF indication.

Certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. Tropicalisation class 2 per EN 61009. Limitation class 3. Electrical and mechanical durability both rated at 20,000 cycles. Storage temperature range -40 to +60 °C.

Frequently asked questions

What is the Type AC residual rating on this RCBO?

Type AC means it detects sinusoidal alternating earth-leakage currents only. It will not trip on pulsed DC or smooth DC waveforms, so for loads with power electronics (VFDs, LED drivers, UPS) a Type A or Type B device is required.

MPN
A9N19675