Skip to main content
Schneider Electric A9N19677 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19677 DPN N Vigi RCBO, 25A B-Curve 30m

MPNA9N19677
Obsolete

Schneider Electric Acti9 DPN N Vigi RCBO, A9N19677, 1P+N, 25 A, B-curve, 300 mA Type AC earth-leakage, 6 kA Icn, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N19677 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19677 — Electrical Ratings
ParameterValue
Rated current (In)25 A at 30 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability10000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19677 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19677 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19677 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19677 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1 EN/IEC 61009-1

Product details

The A9N19677 is a complete RCBO — overcurrent and earth-leakage protection in one 1P+N module. Rated 25 A at 30 °C with a B-curve magnetic trip (3...5 x In) and 300 mA Type AC residual current detection. Breaking capacity is 6 kA Icn at 230 V AC, 50/60 Hz, per EN/IEC 61009. No holes in the box — it ships ready for the DIN rail.

The 300 mA sensitivity is a fire-protection level, not personnel protection (30 mA would be required for that). B-curve trips at 3–5x In, suited for resistive and lighting loads with modest inrush; if your circuit feeds motor or transformer loads, a C-curve would be the better call.

Panel integration

Neutral is fixed left, line right. Operating altitude is 2000 m; derate above that. Ambient storage range is -40 to 60 °C.

Frequently asked questions

What is A9N19677's Type AC detection?

Type AC means it detects sinusoidal AC residual currents only. It is the standard type for general distribution where no pulsed or smooth DC leakage is present.

What is the breaking capacity of A9N19677?

6 kA Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009. Verify your prospective short-circuit current stays under this.

Where can I buy A9N19677 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does A9N19677 carry?

Certified to EN/IEC 61009-2-1 and EN/IEC 61009-1. Tropicalisation class 2 and limitation class 3 per EN 61009. Pollution degree 3.

MPN