Schneider Electric A9N19686 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19686 DPN N Vigi RCBO, 20 A, 30 mA, Ty

MPNA9N19686
Obsolete

Schneider Electric Acti9 DPN N Vigi RCBO, Type AC, C-curve, 20 A, 300 mA, 6 kA, 1P+N, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N19686 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19686 — Electrical Ratings
ParameterValue
Rated current (In)20 A at 30 °C
Rated operational voltage (Ue)230 V AC
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19686 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19686 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19686 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19686 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1 EN/IEC 61009-1

Product details

The 300 mA sensitivity (IΔn) is the residual-current threshold — it catches leakage to earth but is less sensitive than a 30 mA unit, so it suits submain or outgoer circuits where some natural leakage is expected and you want to avoid spurious trips. The Type AC residual-current detection means it trips on sinusoidal AC leakage only — not on pulsed DC or smooth DC. That is fine for circuits feeding resistive loads, heaters, and standard AC motors, but if the downstream equipment includes variable-speed drives, UPS systems, or LED drivers that can generate DC fault currents, you need a Type A or Type B RCBO instead.

Mounting and wiring in the enclosure

The toggle gives clear ON/OFF indication, and the contact-position indicator confirms the state even with the cover closed. Operating altitude is 2000 m; above that, dielectric strength and cooling derate.

Frequently asked questions

What is the A9N19686's breaking capacity?

6000 A Icn at 230 V AC, conforming to EN 61009.

What is the earth-leakage sensitivity of the A9N19686?

300 mA, Type AC, instantaneous trip — no intentional time delay.

Where can I buy the A9N19686 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
A9N19686