A9N19687 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19687 — Electrical Ratings
ParameterValue
Rated current (In)25 A at 30 °C
Rated operational voltage (Ue)230 V AC
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability10000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19687 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19687 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19687 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19687 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1 EN/IEC 61009-1

Product details

It is rated 25 A at 30 °C with a C-curve magnetic trip (5–10 x In) and 300 mA Type AC earth leakage protection, making it suitable for general-purpose distribution circuits in residential and light commercial panels where sinusoidal AC fault currents are expected. Rated breaking capacity is 6000 A Icn at 230 V AC per EN 61009, sufficient for most final subcircuits in a TN or TT system. The thermal-magnetic trip unit provides instantaneous short-circuit and time-delayed overload protection in one package.

Frequently asked questions

What is A9N19687's listed type (Type AC) on this component line?

The A9N19687 is a Type AC residual current device, meaning it detects sinusoidal AC earth leakage currents only. It is the standard choice for general-purpose circuits without non-sinusoidal or pulsating DC fault content.

What compliance documentation does this brand provide for A9N19687?

The A9N19687 is certified to EN/IEC 61009-2-1 and EN/IEC 61009-1, covering the combined overcurrent and residual current protection requirements for RCBOs. It carries a pollution degree 3 rating and overvoltage category III per those standards.

Where can I buy A9N19687 and get current pricing?

The A9N19687 is available to order through independent distribution. Submit an RFQ for current pricing and availability — landed cost and lead time are confirmed at quote time.

MPN
A9N19687