It is rated 25 A at 30 °C with a C-curve magnetic trip (5–10 x In) and 300 mA Type AC earth leakage protection, making it suitable for general-purpose distribution circuits in residential and light commercial panels where sinusoidal AC fault currents are expected. Rated breaking capacity is 6000 A Icn at 230 V AC per EN 61009, sufficient for most final subcircuits in a TN or TT system. The thermal-magnetic trip unit provides instantaneous short-circuit and time-delayed overload protection in one package.
Schneider Electric A9N19687 DPN N Vigi RCBO, 25 A, 30 mA, Ty
Schneider Electric Acti9 DPN N Vigi, Type AC RCBO, 1P+N, 25 A, C-curve, 300 mA sensitivity, 6 kA Icn at 230 V AC.
Specifications
| Parameter | Value |
|---|---|
| Earth-leakage sensitivity (IΔn) | 300 mA |
| Earth-leakage trip time delay | Instantaneous |
| Residual-current tripping technology | Voltage independent |
| Trip unit technology | Thermal-magnetic |
| Local signalling / indication | ON/OFF indication |
| Parameter | Value |
|---|---|
| Rated current (In) | 25 A at 30 °C |
| Rated operational voltage (Ue) | 230 V AC |
| Poles description | 1P + N |
| Neutral pole position | Left |
| Network type | AC |
| Rated insulation voltage (Ui) | 400 V AC conforming to EN 61009 |
| Rated impulse withstand voltage (Uimp) | 4 kV conforming to EN 61009 |
| Overvoltage category | III |
| Device location in system | Outgoer |
| Electrical durability | 10000 cycles conforming to IEC 61009 |
| Mechanical durability (operating cycles) | 20000 cycles |
| Parameter | Value |
|---|---|
| Product name | DPN Vigi |
| Product / component type | Earth leakage circuit breaker |
| Product range / family | Acti9 |
| Device short name | DPN N Vigi |
| Parameter | Value |
|---|---|
| Mounting support | DIN rail |
| Control type | Toggle |
| Width in 9 mm modules | 4 |
| Terminal connections | Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid |
| Parameter | Value |
|---|---|
| Operating ambient temperature | -5...60 °C |
| Storage ambient temperature | -40...60 °C |
| Pollution degree | 3 conforming to EN 61009 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 2000 m |
| Tropicalisation | 2 conforming to EN 61009 |
| Parameter | Value |
|---|---|
| Standards | EN/IEC 61009-2-1 EN/IEC 61009-1 |
Product details
Frequently asked questions
What is A9N19687's listed type (Type AC) on this component line?
The A9N19687 is a Type AC residual current device, meaning it detects sinusoidal AC earth leakage currents only. It is the standard choice for general-purpose circuits without non-sinusoidal or pulsating DC fault content.
What compliance documentation does this brand provide for A9N19687?
The A9N19687 is certified to EN/IEC 61009-2-1 and EN/IEC 61009-1, covering the combined overcurrent and residual current protection requirements for RCBOs. It carries a pollution degree 3 rating and overvoltage category III per those standards.
Where can I buy A9N19687 and get current pricing?
The A9N19687 is available to order through independent distribution. Submit an RFQ for current pricing and availability — landed cost and lead time are confirmed at quote time.