Schneider Electric A9N19688 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N19688 DPN N Vigi RCBO, 32A C-Curve 30m

MPNA9N19688
Active

Schneider Electric Acti9 DPN N Vigi RCBO, 1P+N, 32 A, C-curve, 300 mA Type AC residual current, 6 kA breaking capacity, DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9N19688 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Trip unit technologyThermal-magnetic
Local signalling / indicationON/OFF indication
A9N19688 — Electrical Ratings
ParameterValue
Rated current (In)32 A at 30 °C
Rated operational voltage (Ue)230 V AC
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Rated insulation voltage (Ui)400 V AC conforming to EN 61009
Rated impulse withstand voltage (Uimp)4 kV conforming to EN 61009
Overvoltage categoryIII
Device location in systemOutgoer
Electrical durability10000 cycles conforming to IEC 61009
Mechanical durability (operating cycles)20000 cycles
A9N19688 — Identification
ParameterValue
Product nameDPN Vigi
Product / component typeEarth leakage circuit breaker
Product range / familyActi9
Device short nameDPN N Vigi
A9N19688 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid
A9N19688 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
Pollution degree3 conforming to EN 61009
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to EN 61009
A9N19688 — Approvals
ParameterValue
StandardsEN/IEC 61009-2-1 EN/IEC 61009-1

Product details

The 32 A rated current and C-curve magnetic trip (5–10× In) mean it handles general-purpose loads like lighting, socket circuits, and small distribution boards where inrush from motor-start or capacitive loads is moderate. The 300 mA sensitivity and Type AC detection mean it trips on sinusoidal AC residual currents only; it is the baseline choice for circuits where no pulsed DC or mixed-frequency leakage is expected (resistive heaters, general sockets, basic lighting). The voltage-independent residual current trip technology means the earth-leakage function operates even if the mains voltage is lost — a safety advantage in fault conditions where the line voltage collapses.

The toggle gives clear ON/OFF indication.

Standards compliance covers EN/IEC 61009-1 and 61009-2-1, which is the harmonized European standard for RCBOs. Tropicalisation class 2 per EN 61009 means it withstands 95 % relative humidity at 55 °C and operates up to 2000 m altitude. The 10,000-cycle electrical durability and 20,000-cycle mechanical durability are standard for this class — the device is built for years of daily switching in a distribution board.

Frequently asked questions

What is the A9N19688's Type AC rating?

The Type AC rating means the residual current detection responds to sinusoidal AC earth-leakage currents only. It is the standard type for circuits without electronic loads that generate pulsed DC or high-frequency leakage.

What compliance documentation does Schneider provide for the A9N19688?

The device is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1, which covers the RCBO standard. Tropicalisation class 2 per EN 61009 is also documented. For specific RoHS, REACH, or UL declarations, request the manufacturer's compliance pack with your RFQ.