Schneider Electric A9N19760

Schneider Electric A9N19760 Acti9 DPN Vigi RCBO, 40 A, B Cur

MPN A9N19760
Obsolete

Schneider Electric Acti9 DPN Vigi RCBO, 1P+N, 40 A, B curve, 6 kA breaking capacity, integrated earth-leakage protection, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19760 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity6000 A Icn at 220...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max70 °C
Temp storage min-30 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-30...70 °C
Pollution degree3

All specifications

A9N19760 additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9N19760 is an Acti9 DPN Vigi RCBO — a combined overcurrent and residual-current device in a single 36 mm-wide module. It protects a single-phase final subcircuit against overload, short-circuit (B-curve magnetic trip at 3 to 5 × In), and earth leakage, all in one clip-on DIN-rail unit. Rated 40 A with a 6 kA breaking capacity at 230 V AC, it is sized for residential or light commercial distribution boards where space is tight and you want one device instead of a separate MCB and RCCB.

The 40 A rated current (In) sets the continuous load ceiling — size the downstream cable and load for that, not above. The B-curve characteristic means the magnetic trip fires between 3 and 5 times In (120 to 200 A), so it suits resistive and general-purpose loads with modest inrush; avoid it on motor or transformer circuits that need a C or D curve. The 6 kA Icn at 230 V AC is the short-circuit breaking capacity per EN/IEC 61009-2-1 — adequate for most domestic and small commercial boards, but verify the prospective fault current at the point of installation. Integrated earth-leakage protection means no separate RCCB needed; the device occupies 4 × 9 mm pitches (36 mm) on the DIN rail, leaving room for other modules in the enclosure. Clip-on mounting to a standard DIN rail, tunnel terminals accepting 0.75 to 16 mm² rigid or 0.33 to 10 mm² flexible, and a tightening torque of 2 N·m.

MPN
A9N19760