A9N19805 Acti9 C120H MCB, 2P, 63A, D Curve, 10kA

MPNA9N19805
Obsolete

Schneider Electric Acti9 C120H, miniature circuit breaker (MCB), 2P, 63 A, D curve, 10 kA breaking capacity, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N19805 — Identification
ParameterValue
Product nameC120
Product rangeActi9
Series / familyActi9
Device short nameC120H
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N19805 — Electrical
ParameterValue
Rated current [In]63 A at 30 °C
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]400 V
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N19805 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In conforming to GB/T 10963.1
Breaking capacity (Icu)10 kA Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icn at 400 V AC 50/60 Hz conforming to GB/T 10963.1
Suitable for isolationYes
Trip unit technologyThermal-magnetic
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N19805 — Mechanical
ParameterValue
9 mm pitches6
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals top or bottom 1...50 mm² rigid without cable end Tunnel type terminals top or bottom 1.5...35 mm² flexible with or without cable end
Terminal tightening torquePower circuit: 3.5 N.m
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N19805 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
A9N19805 — Approvals
ParameterValue
Standards / complianceGB/T 10963.1 EN/IEC 60898-1

Product details

The Schneider Electric A9N19805 is an Acti9 C120H miniature circuit breaker (MCB) with 2 poles, rated 63 A at 30 °C, D curve, and a 10 kA breaking capacity at 400 V AC per IEC 60898-1. The D curve means its magnetic trip threshold is 10–14× In, suited for loads with high inrush current like motors or transformers — the breaker holds through the start-up spike and trips only on sustained overload or short circuit.

Deployment Context

The clip-on mounting and 6-module width (9 mm pitches) fit standard DIN-rail enclosures. The 73 mm depth leaves clearance for shallow gland plates. Rated for isolation (suitability for isolation: yes) with a contact position indicator, so it doubles as a visible-break disconnect in distribution panels.

Frequently asked questions

How do I get current pricing and availability for A9N19805?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through our independent sourcing network.

What is A9N19805's breaking capacity?

10 kA Icn at 400 V AC 50/60 Hz per IEC 60898-1 and GB/T 10963.1.

What does the D curve mean on this breaker?

The D curve sets the magnetic trip threshold at 10–14× In (630–882 A for this 63 A unit), designed for loads with high inrush like motors, transformers, or welding equipment.

MPN