Schneider Electric A9N19845 — 2-Pole MCB (DIN Rail)

A9N19845 Acti9 C120L MCB, 2P, 80A, D Curve, 15kA

MPNA9N19845
Obsolete

Schneider Electric Acti9 C120L miniature circuit breaker, A9N19845, 2P, 80 A, D curve, 15 kA Icn at 400 V AC, DIN rail clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N19845 — Identification
ParameterValue
Product nameC120
Product rangeActi9
Series / familyActi9
Device short nameC120L
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N19845 — Electrical
ParameterValue
Rated current [In]80 A at 30 °C
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]400 V
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N19845 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In conforming to GB/T 10963.1 12 x In +/- 20 % conforming to GB/T 14048.2
Breaking capacity (Icu)15 kA Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icn at 400 V AC 50/60 Hz conforming to GB/T 10963.1 15 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 400 V AC 50/60 Hz conforming to GB/T 14048.2
Suitable for isolationYes
Trip unit technologyThermal-magnetic
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N19845 — Mechanical
ParameterValue
9 mm pitches6
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals top or bottom 1...50 mm² rigid without cable end Tunnel type terminals top or bottom 1.5...35 mm² flexible with or without cable end
Terminal tightening torquePower circuit: 3.5 N.m
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N19845 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
A9N19845 — Approvals
ParameterValue
Standards / complianceGB 10963.1 EN/IEC 60898-1 GB/T 14048.2 EN/IEC 60947-2

Product details

The Schneider Electric A9N19845 is a 2-pole miniature circuit breaker from the Acti9 C120L range, rated 80 A at 30 °C with a D trip curve. The 15 kA Icn breaking capacity at 400 V AC (conforming to EN/IEC 60898-1) and 15 kA Icu (conforming to EN/IEC 60947-2) means it can safely interrupt fault currents up to that level without welding contacts or cascading failure upstream — essential for panel coordination studies. Rated operational voltage is 400 V AC, insulation voltage 500 V AC, with a 6 kV impulse withstand rating. The thermal-magnetic trip unit provides both overload (thermal) and short-circuit (magnetic) protection in one device. Dual-standard certified to GB 10963.1 / EN/IEC 60898-1 for household-type MCB duty and GB/T 14048.2 / EN/IEC 60947-2 for industrial circuit-breaker application — so it qualifies for both residential distribution boards and industrial panel builds where the higher 60947-2 rating is required for SCCR.

Clip-on mounting to DIN rail, 6 module pitches (9 mm each = 54 mm wide). Tunnel terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible. The toggle switch provides local ON/OFF indication and a contact position indicator confirms isolation status — suitable for lockout/tagout when used as an isolator (marked suitable for isolation per the standard).

Frequently asked questions

Where can I buy A9N19845 and what is the price?

This part is sourced and quoted to order through independent distribution against an RFQ. Current pricing and availability are confirmed at quote time — no stock count or price figure is stated here because the market picture changes with each inquiry.

What is the breaking capacity of A9N19845?

15 kA Icn at 400 V AC conforming to EN/IEC 60898-1, and 15 kA Icu at 400 V AC conforming to EN/IEC 60947-2 — the same 15 kA figure under both standards, so it qualifies for both household and industrial panel SCCR requirements.

What does the D curve mean on this MCB?

The D curve sets magnetic tripping at 10–14 × In (per GB/T 10963.1), meaning it tolerates high inrush currents from motor starts, transformer energization, or discharge lighting without nuisance tripping — the right choice for inductive and capacitive loads where a B or C curve would trip on startup.

MPN
A9N19845