Schneider Electric A9N19853 — 2-Pole MCB (DIN Rail)

A9N19853 Acti9 C120L MCB, 2P, 100A, D Curve, 15kA

MPNA9N19853
Obsolete

Schneider Electric Acti9 C120L miniature circuit breaker, A9N19853, 2-pole, 100 A, D curve, 15 kA breaking capacity at 400 V AC, thermal-magnetic trip, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N19853 — Identification
ParameterValue
Product nameC120
Product rangeActi9
Series / familyActi9
Device short nameC120L
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N19853 — Electrical
ParameterValue
Rated current [In]100 A at 30 °C
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]400 V
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N19853 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In conforming to GB/T 10963.1 12 x In +/- 20 % conforming to GB/T 14048.2
Breaking capacity (Icu)15 kA Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icn at 400 V AC 50/60 Hz conforming to GB/T 10963.1 15 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 400 V AC 50/60 Hz conforming to GB/T 14048.2
Suitable for isolationYes
Trip unit technologyThermal-magnetic
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N19853 — Mechanical
ParameterValue
9 mm pitches6
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals top or bottom 1...50 mm² rigid without cable end Tunnel type terminals top or bottom 1.5...35 mm² flexible with or without cable end
Terminal tightening torquePower circuit: 3.5 N.m
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N19853 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
A9N19853 — Approvals
ParameterValue
Standards / complianceGB 10963.1 EN/IEC 60898-1 GB/T 14048.2 EN/IEC 60947-2

Product details

The A9N19853 is a 2-pole miniature circuit breaker from the Acti9 C120L series, rated 100 A at 30 °C with a D trip curve (magnetic trip 10–14 × In). That dual-standard rating means it qualifies for residential-distribution boards (60898-1) and industrial panel feeders (60947-2) — one part covers both specification regimes.

The D curve's 10–14× In magnetic threshold means it tolerates the starting surge of motor loads without nuisance tripping — a C curve (5–10× In) would trip on the same inrush. Terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible, torqued to 3.5 N·m. The 2-pole form factor occupies 6 × 9 mm pitch modules (54 mm) on the DIN rail. Mechanical endurance is 20,000 cycles; electrical endurance is 5,000 cycles — sufficient for distribution duty where the breaker operates infrequently.

Frequently asked questions

Where can I buy the A9N19853 and how is it quoted?

The A9N19853 is sourced through independent distribution and surplus channels. It is quoted to order against an RFQ — availability and current pricing are confirmed at quote time.

What are the key specifications of the A9N19853?

It is a 2-pole, 100 A miniature circuit breaker with a D curve, 15 kA breaking capacity at 400 V AC, thermal-magnetic trip, and DIN rail mounting.

What standards does the A9N19853 comply with?

It is certified to GB 10963.1, EN/IEC 60898-1, GB/T 14048.2, and EN/IEC 60947-2 — covering both household and industrial application standards.

MPN
A9N19853