Schneider Electric A9N1P01CGN

Schneider Electric A9N1P01CGN Acti9 xC60 MCB, 1A Curve C, 1P

MPN A9N1P01CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P01CGN, 1 A rated current, curve C, 1 pole, 10 kA breaking capacity at 240 V AC, clip-on 35 mm DIN rail mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P01CGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9N1P01CGN additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P01CGN is a 1 A miniature circuit breaker from the Acti9 xC60 series, single-pole, curve C, designed for AC distribution networks. It clips onto a 35 mm DIN rail and occupies two 9 mm pitches (18 mm wide). The 10 kA Icn breaking capacity at 240 V AC per IS/IEC 60898-1 means it can safely interrupt fault currents up to that level on a residential or light commercial final subcircuit — adequate for most domestic lighting and socket-outlet protection in regions following IEC 60898-1.

Curve C and trip characteristics

Curve C means the magnetic trip operates at 5 to 10 times In (5–10 A for this 1 A unit). That suits loads with moderate inrush — think lighting banks, small transformers, or general-purpose socket outlets. The thermal-magnetic trip element handles overloads; the magnetic coil clears short-circuits. For a 1 A breaker, the 5–10× In band gives a good balance between nuisance ride-through and fast fault clearance on typical final circuits.

The 18 mm width (two 9 mm pitches) fits standard modular enclosures. Tunnel-type terminals at bottom accept up to 25 mm² rigid or 16 mm² flexible cable; strip length 13 mm. Tightening torque 2 N·m.

MPN