Skip to main content
Schneider Electric A9N1P01CIN

Schneider Electric A9N1P01CIN Acti9 xC60 MCB, 1 A, 1P, C-Cur

MPN A9N1P01CIN
Active

Schneider Electric Acti9 xC60 series, A9N1P01CIN, miniature circuit breaker, 1 A, 1P, C-curve, 10 kA Icu at 240 V AC, 15 kA at 48 V DC, clip-on 35 mm DIN rail, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P01CIN key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

A9N1P01CIN additional specifications
ParameterValue
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P01CIN is a 1 A, 1-pole miniature circuit breaker from the Acti9 xC60 series, built to IS/IEC 60947-2. It clips onto a 35 mm DIN rail — 18 mm wide, 85 mm tall, 77.5 mm deep — and uses a thermal-magnetic trip unit with a C-curve (magnetic trip at 8 x In +/- 20 %). Overvoltage category IV means it's rated for the mains entrance, not just downstream sub-distribution.

The C-curve holds through 5x to 10x In before instant tripping, so it tolerates the inrush of a 24 VDC power supply or a contactor coil without nuisance trips. IS/IEC 60947-2 utilisation category A means it's not intended for motor-starting duty — it's a distribution breaker, not a motor-protective device.

Tightening torque 2 N.m. Pollution degree 3 — suitable for industrial atmospheres with conductive pollution, provided the enclosure keeps out direct contamination.

MPN
A9N1P01CIN