Skip to main content
Schneider Electric A9N1P02CGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P02CGN Acti9 MCB, 2A, C-Curve, 1P

MPNA9N1P02CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P02CGN, 2 A rated, C-curve, 1-pole, 10 kA breaking capacity at 240 V AC, 50/60 Hz, clip-on 35 mm DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P02CGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P02CGN — Electrical & Protection
ParameterValue
Rated current (In)2 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P02CGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P02CGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P02CGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The A9N1P02CGN is a Schneider Electric Acti9 xC60 miniature circuit breaker — a 2 A, C-curve, 1-pole unit rated for 220...240 V AC at 50/60 Hz.

Breaking capacity and standards

Breaking capacity is 10000 A Icn at 240 V AC, certified to IS/IEC 60898-1.

Durability and environmental rating

Rated for 20000 electrical and 20000 mechanical cycles — that's a solid service life for a distribution MCB; you're not changing it out every few years in a normal panel. That's a real plus for coastal plants or unconditioned electrical rooms.

Termination and wiring

That's standard for this class — your panel wireman can land it with a common screwdriver, no special tooling.

Frequently asked questions

How do I get current pricing and availability for A9N1P02CGN?

Submit an RFQ against this order code. Pricing and stock are confirmed at quote time through independent distribution channels; no published price or live inventory count is carried on this listing.

What is A9N1P02CGN's listed depth?

The depth is 77.5 mm, with a height of 85 mm and width of 18 mm (2 x 9 mm pitches).

What is the closest alternative to A9N1P02CGN in the Acti9 family?

Within the Acti9 xC60 range, the closest sibling would be a different current rating or curve code — same 1P, 18 mm wide, same breaking capacity and DIN-rail clip. The C-curve and 2 A rating are the distinguishing parameters; a B-curve version would trip faster on inrush, a D-curve would tolerate higher surge. No pin-compatible alternative exists outside the Acti9 family without changing the panel layout.

What compliance documentation does Schneider provide for A9N1P02CGN?

The breaker is certified to IS/IEC 60898-1. Standard documentation includes the declaration of conformity and the product datasheet. RoHS and REACH compliance is standard for Schneider Acti9 products, though specific certificates should be requested with the RFQ.

MPN
A9N1P02CGN