Skip to main content
Schneider Electric A9N1P03CGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P03CGN Acti9 xC60 MCB, 3 A C-Curve 1P

MPNA9N1P03CGN
Active

Schneider Electric Acti9 xC60, A9N1P03CGN, miniature circuit breaker, 1P, 3 A, C-curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P03CGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P03CGN — Electrical & Protection
ParameterValue
Rated current (In)3 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P03CGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P03CGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P03CGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P03CGN is an Acti9 xC60 miniature circuit breaker — a 1-pole, 3 A thermal-magnetic MCB with a C-curve (magnetic tripping between 5 and 10 times In).

Rated breaking capacity is 10 kA Icn at 240 V AC, 50/60 Hz, per IS/IEC 60898-1. That's the standard domestic and light commercial short-circuit rating for this class — adequate for most final distribution boards where the upstream device limits prospective fault current. The C-curve means it holds magnetic trips for inrush-heavy loads (small motors, transformers, lighting ballasts) while still clearing fast on hard shorts.

Depth is 77.5 mm, height 85 mm. Overvoltage category IV (suitable for main incoming panels). Pollution degree 3 (condensation and conductive pollution allowed). Tightening torque 2 N·m.

Frequently asked questions

Where can I buy A9N1P03CGN and how do I get a price?

The A9N1P03CGN is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing.

What is A9N1P03CGN's breaking capacity?

The A9N1P03CGN has a rated breaking capacity of 10 kA Icn at 240 V AC, 50/60 Hz, conforming to IS/IEC 60898-1.

What is the C-curve on this MCB?

The C-curve means magnetic tripping occurs between 5 and 10 times the rated current (In), so for the 3 A version, magnetic trip is between 15 A and 30 A. This suits loads with moderate inrush like small motors or lighting.

What is the A9N1P03CGN's rated current and voltage?

Rated current (In) is 3 A. Rated operational voltage (Ue) is 220...240 V AC, 50/60 Hz. Single-pole, single-phase application.