Skip to main content
Schneider Electric A9N1P04CGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P04CGN Acti9 xC60 MCB, 4 A, C Curve,

MPNA9N1P04CGN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, A9N1P04CGN, 1P, 4 A, C curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P04CGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P04CGN — Electrical & Protection
ParameterValue
Rated current (In)4 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P04CGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P04CGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P04CGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P04CGN is a 1-pole miniature circuit breaker from the Acti9 xC60 range, rated at 4 A with a C-curve trip characteristic. It clips onto a standard 35 mm DIN rail and is built for distribution in residential and commercial AC networks at 220–240 V, 50/60 Hz.

Rated breaking capacity is 10 kA Icn at 240 V AC, certified to IS/IEC 60898-1. The limitation class is 3 per the same standard, which means it lets through less energy during a short-circuit than a class 1 or 2 device, helping with downstream coordination.

Integration and wiring

Mounts via clip-on to 35 mm DIN rail.

Frequently asked questions

What is the breaking capacity of A9N1P04CGN?

10 kA Icn at 240 V AC, 50/60 Hz, certified to IS/IEC 60898-1. This is the maximum fault current the breaker can safely interrupt at that voltage.

What does the C curve mean on this breaker?

The C curve means the magnetic trip is set to operate between 5 and 10 times the rated current (20–40 A for this 4 A unit). It's designed for circuits with moderate inrush, such as small motors, fluorescent lighting, or general-purpose socket outlets.

What compliance documentation is available for A9N1P04CGN?

The breaker is certified to IS/IEC 60898-1 and carries tropicalisation treatment per IEC 60068-1. Standard compliance documentation (declaration of conformity, CE marking) is available from the manufacturer's support portal.

Where can I buy A9N1P04CGN?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
A9N1P04CGN