Schneider Electric A9N1P06BGN — 1-Pole MCB (DIN Rail)

Schneider A9N1P06BGN Acti9 xC60 MCB, 6A Curve B 1P, 10kA

MPNA9N1P06BGN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, 1P, 6 A, B curve, 10 kA at 240 V AC, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P06BGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P06BGN — Electrical & Protection
ParameterValue
Rated current (In)6 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P06BGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P06BGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P06BGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

Schneider Electric A9N1P06BGN is a 1-pole miniature circuit breaker from the Acti9 xC60 series, rated 6 A with a B tripping curve.

B-curve tripping and thermal-magnetic action

The thermal-magnetic trip unit handles sustained overloads via the bimetal strip and short-circuits via the solenoid. The 3...5 x In magnetic threshold means it holds through motor inrush only on the smallest fractional-horsepower motors; for motor circuits a C or D curve is the usual pick.

Occupies 2 x 9 mm pitches (18 mm wide) on the DIN rail — standard single-module footprint. Height of 85 mm and depth of 77.5 mm leave enough clearance under a 100 mm deep enclosure lid.

Listed as current production. No end-of-life notice or successor code has been issued. This is a standard catalogue item in the Acti9 family, widely specified across South Asia and the Middle East where IS/IEC 60898-1 is the governing standard.

Frequently asked questions

What is the breaking capacity of this MCB?

10,000 A Icn at 240 V AC, 50/60 Hz, conforming to IS/IEC 60898-1. This is the rated short-circuit capacity the breaker can safely interrupt.

Where can I buy A9N1P06BGN and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm price and lead time.

What compliance documentation does this breaker carry?

Certified to IS/IEC 60898-1. The Acti9 xC60 series also carries tropicalisation treatment per IEC 60068-1 (class 2) for humid environments. RoHS and REACH compliance documentation is typically available from the manufacturer's product page for this series.