Schneider Electric A9N1P10CGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P10CGN Acti9 xC60 MCB, 10A C-Curve, 1

MPNA9N1P10CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P10CGN, 1P, 10 A, C-curve, 10 kA breaking capacity, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P10CGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P10CGN — Electrical & Protection
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P10CGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P10CGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P10CGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P10CGN is a 1-pole miniature circuit breaker from the Acti9 xC60 family, rated 10 A with a C-curve trip characteristic. That 10 kA Icn breaking capacity at 240 V AC (IS/IEC 60898-1) tells you it can safely interrupt a fault current up to 10,000 A without welding its contacts or rupturing the case; the standard certifies it for final-distribution boards in residential and light commercial panels. The thermal-magnetic trip unit handles overloads (thermal bimetal) and short-circuits (solenoid) in one package — no separate relay needed.

The 18 mm width (2 modules) means you can plan fill factor: a 12-way board takes 12 of these single-pole breakers plus a main switch. The toggle actuator gives local ON/OFF indication — no auxiliary contact needed for visual status. Earth-leakage protection requires a separate block (not integrated), so if RCD protection is needed, plan a downstream or adjacent residual-current device.

Frequently asked questions

What is the breaking capacity of the A9N1P10CGN?

The A9N1P10CGN has a rated breaking capacity of 10,000 A Icn at 240 V AC, 50/60 Hz, certified to IS/IEC 60898-1. That means it can safely interrupt a fault current up to 10 kA at the rated voltage.

What does the C-curve on this MCB mean?

The C-curve means the magnetic trip threshold is 5 to 10 times the rated current (50–100 A for this 10 A breaker). It is designed for circuits with moderate inrush — lighting banks, small motors, transformers — where a B-curve would nuisance-trip but a D-curve would be too slow for cable protection.

Where can I buy the A9N1P10CGN?

The A9N1P10CGN is sourced and quoted to order through our independent distribution channel. Submit an RFQ for current pricing and availability — we confirm both at quote time.