Skip to main content
Schneider Electric A9N1P16DIN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P16DIN Acti9 xC60 MCB, 16 A, 1P, D Cu

MPNA9N1P16DIN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, 1P, 16 A, D curve, 10 kA Icu at 240 V AC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P16DIN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P16DIN — Electrical & Protection
ParameterValue
Rated current (In)16 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P16DIN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P16DIN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P16DIN — Approvals
ParameterValue
Conformity standardsIS/IEC 60947-2
A9N1P16DIN — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IS/IEC 60947-2
[Uimp] rated impulse withstand voltage4 kV conforming to IS/IEC 60947-2

Product details

The Schneider Electric A9N1P16DIN is an Acti9 xC60 miniature circuit breaker — a 1-pole, 16 A thermal-magnetic MCB with a D tripping curve, rated to IS/IEC 60947-2.

Breaking capacity is 10 kA Icu at 220–240 V AC 50/60 Hz, 15 kA Icu at 12–48 V DC, and 6 kA Icu at 60 V DC — all per IS/IEC 60947-2. For DC circuits, the 15 kA at 48 V covers common control-voltage rails, but the drop to 6 kA at 60 V means you need to check the actual fault current if running a 60 VDC bus.

That's a single-module footprint — standard for a 1P MCB in a distribution board.

Frequently asked questions

How do I get current pricing and availability for A9N1P16DIN?

The A9N1P16DIN is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is A9N1P16DIN's listed depth?

The listed depth is 77.5 mm, with a height of 85 mm and a width of 18 mm (2 x 9 mm pitches).

What is A9N1P16DIN's listed range?

It belongs to the Acti9 range, specifically the xC60 device short name, designed for distribution applications.

What compliance documentation does this brand provide for A9N1P16DIN?

The MCB is certified to IS/IEC 60947-2, with tropicalisation class 2 per IEC 60068-1 and pollution degree 3. It is suitable for isolation per the same standard. Specific RoHS/REACH/UL documentation should be confirmed at quote time.

MPN
A9N1P16DIN