Schneider Electric A9N1P20BGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P20BGN Acti9 xC60 MCB, 20A 1P B-Curve

MPNA9N1P20BGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P20BGN, 1P, 20 A, B-curve, 10 kA breaking capacity, clip-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P20BGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P20BGN — Electrical & Protection
ParameterValue
Rated current (In)20 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P20BGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P20BGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P20BGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P20BGN is a 1-pole Acti9 xC60 miniature circuit breaker rated 20 A with a B-curve trip characteristic. Breaking capacity is 10000 A Icn at 240 V AC 50/60 Hz per IS/IEC 60898-1. B-curve magnetic trip operates at 3 to 5 times In. Thermal-magnetic trip unit provides overload and short-circuit protection.

Height 85 mm, depth 77.5 mm. Tightening torque 2 N·m. IP20 finger-safe terminals. Pollution degree 3, overvoltage category IV — suitable for the main distribution board environment where conductive pollution and transient overvoltages are expected.

Frequently asked questions

What compliance documentation does this brand provide for A9N1P20BGN?

The part is certified to IS/IEC 60898-1 and carries tropicalisation per IEC 60068-1 (class 2). The manufacturer provides a declaration of conformity; specific RoHS/REACH/UL documentation should be requested at quote time.

MPN