Skip to main content
Schneider Electric A9N1P25BGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P25BGN Acti9 xC60 MCB, 25 A, 1P, B-Cu

MPNA9N1P25BGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, 1P, 25 A, B-curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail, IP20, white.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P25BGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P25BGN — Electrical & Protection
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P25BGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)2 N.m
A9N1P25BGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P25BGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P25BGN is a 1-pole miniature circuit breaker from the Acti9 xC60 range, rated 25 A with a B-curve trip characteristic. It clips onto a standard 35 mm DIN rail and occupies 2 x 9 mm pitches (18 mm wide), so it slots into any distribution board without surprises.

Rated 25 A with a B-curve — magnetic trip between 3 and 5 times In — so it's sized for residential and light commercial final circuits where inrush is low (lighting, socket outlets). The 10 kA Icn breaking capacity at 240 V AC meets IS/IEC 60898-1 for branch-circuit fault clearing up to that level; above that, you need an upstream limiting device. Thermal-magnetic trip unit handles overloads via the bimetal strip and short-circuits via the solenoid — no electronics to fail, no auxiliary supply needed. Rated operational voltage is 220...240 V AC 50/60 Hz, so it's a straight swap for any 1P 25 A B-curve MCB on a single-phase line. IP20 means finger-safe terminals but no protection against dripping water — keep it inside the enclosure.

Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible; strip 13 mm and torque to 2 N·m. Toggle control with ON/OFF indication gives clear visual status without a multimeter.

Frequently asked questions

Where can I buy A9N1P25BGN and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is A9N1P25BGN's listed depth?

Depth is 77.5 mm.

What is A9N1P25BGN's range?

It belongs to the Acti9 range, specifically the xC60 series.

What compliance documentation does this brand provide for A9N1P25BGN?

The breaker is certified to IS/IEC 60898-1 and tropicalised per IEC 60068-1. Standard Schneider documentation includes the declaration of conformity; RoHS and REACH compliance data is available on request.

MPN
A9N1P25BGN