Skip to main content
Schneider Electric A9N1P32DGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P32DGN Acti9 xC60 MCB, D Curve, 32 A,

MPNA9N1P32DGN
Active

Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N1P32DGN, 1P, D curve, 32 A rated current, 10 kA breaking capacity at 240 V AC, clip-on 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N1P32DGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P32DGN — Electrical & Protection
ParameterValue
Rated current (In)32 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P32DGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)3.5 N.m
A9N1P32DGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P32DGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P32DGN is a single-pole miniature circuit-breaker from the Acti9 range, carrying the xC60 device short name. It clips onto a standard 35 mm DIN rail and occupies 18 mm width at 85 mm height and 77.5 mm depth — two 9 mm pitches. Rated 32 A with a D tripping curve, it is built for distribution duty on AC networks at 220…240 V, 50/60 Hz.

Overvoltage category IV and pollution degree 3 mean this breaker is rated for the main distribution board — not just sub-panels — where transient overvoltages are highest and the environment may be conductive or dusty. The thermal-magnetic trip unit provides both overload (thermal bimetal) and short-circuit (magnetic) protection in one compact package. Tropicalisation level 2 per IEC 60068-1 adds mould and corrosion resistance for humid or coastal installations. The IP20 finger-safe terminals protect personnel during panel work.

Frequently asked questions

What is the breaking capacity of A9N1P32DGN?

10 000 A Icn at 240 V AC, 50/60 Hz, conforming to IS/IEC 60898-1.

Where can I buy A9N1P32DGN and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What does the D curve mean for this MCB?

Magnetic trip operates at 10…14 x In, so it handles high inrush loads like motors or transformers without nuisance tripping.

MPN