Skip to main content
Schneider Electric A9N1P40DIN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P40DIN Acti9 xC60 MCB, 40 A D Curve,

MPNA9N1P40DIN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, 1P, 40 A, D curve, 10 kA Icu at 240 V AC, clip-on 35 mm DIN rail, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P40DIN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P40DIN — Electrical & Protection
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P40DIN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)3.5 N.m
A9N1P40DIN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P40DIN — Approvals
ParameterValue
Conformity standardsIS/IEC 60947-2
A9N1P40DIN — Electrical
ParameterValue
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IS/IEC 60947-2
[Uimp] rated impulse withstand voltage4 kV conforming to IS/IEC 60947-2

Product details

The D curve means magnetic tripping occurs at 12 x In (480 A), so it tolerates the inrush of motor or transformer loads without nuisance trips. Breaking capacity is 10 kA Icu at 220–240 V AC, 15 kA at 12–48 V DC, and 6 kA at 60 V DC — enough for most commercial and light industrial panelboards where the prospective fault current stays under those limits. The thermal-magnetic trip unit handles both overload (thermal bimetal) and short-circuit (solenoid) protection in one package.

DIN rail fit and wiring

At 18 mm wide (2 x 9 mm pitches) and 77.5 mm deep, this breaker occupies one standard module on a 35 mm DIN rail. The bottom terminals use a biconnect/tunnel design that can also loop a busbar through. IP20 finger-safe protection means it's intended for enclosed panels, not open wet areas.

Frequently asked questions

Where can I buy A9N1P40DIN and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is the closest alternative to A9N1P40DIN in the Acti9 family?

The closest sibling is another Acti9 xC60 1P 40 A breaker with a different curve — the C-curve version (magnetic trip at 5–10 x In) is the standard choice for general-purpose distribution. The D-curve variant is selected specifically for high-inrush loads like motors or transformers.

MPN
A9N1P40DIN