Schneider Electric A9N1P50CGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P50CGN Acti9 xC60 MCB, 50 A, 1P, C Cu

MPNA9N1P50CGN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, 1P, 50 A, C curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail, white.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N1P50CGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P50CGN — Electrical & Protection
ParameterValue
Rated current (In)50 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P50CGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)3.5 N.m
A9N1P50CGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P50CGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P50CGN is a 1-pole Acti9 xC60 miniature circuit breaker rated 50 A with a C curve (magnetic trip 5–10 × In). It breaks 10,000 A Icn at 240 V AC 50/60 Hz per IS/IEC 60898-1, which covers typical residential and light commercial distribution panel faults — enough clearing capacity for most final subcircuits without cascading upstream.

The 77.5 mm depth and 85 mm height fit standard distribution board cutouts. Tightening torque 3.5 N·m.

Frequently asked questions

Who supplies A9N1P50CGN and how is it quoted for volume purchases?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Volume pricing and lead time are confirmed at quote time.

What is A9N1P50CGN's rated breaking capacity?

10,000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1. That is the standard breaking capacity for a final-circuit MCB under that standard.

What compliance documentation does this brand provide for A9N1P50CGN?

The breaker is certified to IS/IEC 60898-1 and carries tropicalisation class 2 per IEC 60068-1. Standard Schneider declarations for RoHS and REACH are available on request.

MPN