Skip to main content
Schneider Electric A9N1P63CGN — 1-Pole MCB (DIN Rail)

Schneider Electric A9N1P63CGN Acti9 xC60 MCB, 63 A, C-Curve,

MPNA9N1P63CGN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, 63 A, C-curve, 1-pole, 10 kA Icn at 240 V AC, IS/IEC 60898-1, 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N1P63CGN — Identification
ParameterValue
Product nameXC60
Product / component typeMiniature circuit-breaker
Product rangeActi9
Device short namexC60
Poles description1P
Number of protected poles1
Device applicationDistribution
A9N1P63CGN — Electrical & Protection
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N1P63CGN — Mounting & Connection
ParameterValue
Terminal connections / wire rangeBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Mounting support35 mm DIN rail
Mounting modeClip-on
Width18 mm
Height85 mm
Depth77.5 mm
Tightening torque (by circuit)3.5 N.m
A9N1P63CGN — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20
A9N1P63CGN — Approvals
ParameterValue
Conformity standardsIS/IEC 60898-1

Product details

The Schneider Electric A9N1P63CGN is an Acti9 xC60 miniature circuit breaker — a 1-pole, 63 A thermal-magnetic MCB with a C-curve trip characteristic, built to IS/IEC 60898-1 for distribution in residential and light commercial panels. The 63 A rating means it protects a branch circuit carrying up to that continuous current; the C-curve (magnetic trip between 5 and 10 times In) is the standard choice for inductive loads like small motors, pumps, and lighting ballasts where inrush is moderate.

Clip-on mounting to a standard 35 mm DIN rail, occupying 18 mm width — two 9 mm pitches. That's a single module slot in a consumer unit or distribution board. Tightening torque is 3.5 N.m, and wire strip length is 13 mm for top or bottom connection. IP20 finger-safe front is standard for enclosed panels; no washdown rating here, so keep it behind a panel door.

Frequently asked questions

What is the breaking capacity of A9N1P63CGN?

The A9N1P63CGN has a rated breaking capacity of 10,000 A Icn at 240 V AC, 50/60 Hz, conforming to IS/IEC 60898-1. That's the maximum fault current it can safely interrupt under standard test conditions.

What does the C-curve mean on this MCB?

The C-curve means the magnetic trip operates at 5 to 10 times the rated current (In). For this 63 A breaker, that's 315 to 630 A instantaneous trip — suited for circuits with moderate inrush like small motors, transformers, and lighting.

What standards does A9N1P63CGN comply with?

This MCB complies with IS/IEC 60898-1, the Indian and international standard for miniature circuit breakers for overcurrent protection in household and similar installations. Pollution degree 3 and overvoltage category IV are specified for the distribution environment.

Where can I buy A9N1P63CGN and how is it quoted?

The A9N1P63CGN is sourced and quoted to order against an RFQ through independent industrial-automation distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN