Skip to main content
Schneider Electric A9N21366

Schneider Electric A9N21366 DT40N MCB, 16 A, 1P+N, C Curve,

MPN A9N21366
Obsolete

Schneider Electric ProDis DT40N MCB, A9N21366, 1P+N, 16 A, C curve, 6 kA Icn / 10 kA Icu, thermal-magnetic, DIN-rail clip-on, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21366 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50 Hz between phase and neutral
Insulation voltage ui400 V AC 50 Hz
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Pollution degree3 conforming to IEC 60947-2

All specifications

A9N21366 additional specifications
ParameterValue
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It clips onto DIN rail and is built for distribution panels — the thermal-magnetic trip unit handles overloads and short-circuits in a single module width (18 mm). Breaking capacity is 6 kA Icn at 230 V AC per EN/IEC 60898-1, and 10 kA Icu at 230–240 V AC per IEC 60947-2. That dual rating means it qualifies for both residential (60898-1) and industrial (60947-2) applications — useful when a panel must meet both standards without swapping breakers.

At 16 A, this breaker suits branch circuits feeding a mix of resistive and light inductive loads up to roughly 3.5 kW on a 230 V line. Overvoltage category IV qualifies it for the service entrance or main distribution board, not just sub-panels. Tropicalisation level 2 per IEC 60068-1 means the breaker is treated against humidity and fungal growth — relevant for installations in coastal or high-humidity zones where standard breakers may corrode internally.

For volume purchases or BOM freeze, the part is specified into the panel design with full traceability to the Schneider ProDis family. The dual-standard certification (EN/IEC 60898-1 and 60947-2) simplifies compliance documentation across projects.

Neutral is on the left (fixed position). IP20 finger-safe protection (IEC 60529) is standard for enclosed panels. The toggle control gives clear ON/OFF indication. Earth-leakage protection requires a separate block — not built in.

MPN