Skip to main content
Schneider Electric A9N21375

Schneider Electric A9N21375 Prodis DT40 MCB, D Curve, 10 A,

MPN A9N21375
Obsolete

Schneider Electric Prodis DT40 MCB, D curve, 10 A, 1P+N, 6 kA Icn / 10 kA Icu, DIN rail clip-on, EN/IEC 60898-1 & 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21375 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50 Hz between phase and neutral
Insulation voltage ui400 V AC 50 Hz
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Pollution degree3 conforming to IEC 60947-2

All specifications

A9N21375 additional specifications
ParameterValue
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The breaking capacity is 6 kA Icn at 230 V AC per EN/IEC 60898-1 for general-purpose branch-circuit protection, and 10 kA Icu at 230–240 V AC per IEC 60947-2 for industrial panel duty — the higher figure applies when the MCB is used as a standalone industrial device rather than a domestic final-circuit breaker. The 1P+N format switches only the phase; the neutral is a switched neutral that opens with the phase but does not carry an overcurrent trip. This is common in single-phase distribution boards where the neutral must be disconnected for isolation but does not need its own overload protection. Thermal-magnetic trip technology combines a bimetal strip for overload protection (thermal) and a solenoid for short-circuit protection (magnetic). The electrical and mechanical durability are both rated at 20,000 cycles, which is standard for this class of MCB in panel applications.

Clip-on mounting to a DIN rail, 18 mm width (2 x 9 mm pitches), 81 mm height, 78 mm depth. The tunnel-type terminals accept flexible cable up to 10 mm² or rigid up to 16 mm², with a wire stripping length of 13 mm and a tightening torque of 2 N·m. The neutral position is on the left, and the toggle control provides local ON/OFF indication. IP20 rated (finger-safe terminals), suitable for installation inside an enclosed panel.

MPN