Specifications

A9N21379 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50 Hz between phase and neutral
Insulation voltage ui400 V AC 50 Hz
Breaking capacity6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230...240 V AC 50 Hz conforming to IEC 60947-2
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C

All specifications

A9N21379 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9N21379 is a DT40N thermal-magnetic miniature circuit breaker from the Prodis range, rated 32 A with a D tripping curve (magnetic trip between 10 and 14 x In). It is a 1P+N unit — one protected pole plus a switched neutral on the left — and clips onto a DIN rail for panel mounting. The breaker is dual-rated to EN/IEC 60898-1 (6 kA Icn at 230 V AC) and IEC 60947-2 (10 kA Icu at 230…240 V AC), so it can serve both residential-distribution and light-industrial feeder circuits.

The 32 A continuous rating (In) sets the maximum steady load this MCB can carry without tripping. The D curve's 10–14 x In magnetic threshold means it will hold through a motor starting surge of roughly 320–448 A for a few cycles before the thermal element takes over — that's the key spec for motor or transformer branch circuits. The dual breaking capacity matters for coordination: 6 kA Icn is the standard for household panels under EN 60898-1, while 10 kA Icu under IEC 60947-2 gives the headroom needed for industrial panelboards where fault currents can be higher. Pollution degree 3 (conforming to IEC 60947-2) means the breaker is rated for the conductive-dust and humidity conditions typical of control cabinets, not just clean indoor residential use.

Tunnel terminals accept flexible cable 0.33…10 mm² or rigid 0.75…16 mm² upstream and downstream. The neutral position is on the left, and the toggle provides local ON/OFF indication. IP20 finger-safe terminals are standard for enclosed panels.

MPN
A9N21379