Skip to main content
Schneider Electric A9N21483 — Residual Current Breakers (RCCB/RCBO)

A9N21483 Vigi TG40 Add-on RCD, 40A 300mA, Obsolete

MPNA9N21483
Obsolete

Schneider Electric Prodis Vigi TG40 add-on residual current device, 1P+N, 40 A rated, 300 mA sensitivity, Type AC, voltage-independent tripping.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N21483 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationON/OFF indication
A9N21483 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)230 V AC 50 Hz phase to neutral
Poles description1P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)400 V AC 50 Hz conforming to EN 61009-1
Rated impulse withstand voltage (Uimp)6 kV conforming to EN 61009-1
Device location in systemGroup incomer
A9N21483 — Identification
ParameterValue
Product / component typeAdd-on residual current device
Product range / familyProdis
Device short nameVigi TG40
A9N21483 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules2
Terminal connectionsCable upstream 0.75...16 mm² rigid Cable upstream 0.33...10 mm² flexible
Wire stripping length13 mm
Terminal tightening torque2 N.m
Width18 mm
Height82 mm
Depth70 mm
A9N21483 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN 61009-1
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to IEC 60068-1
A9N21483 — Approvals
ParameterValue
StandardsIEC 60947-2 EN 61009-1 EN 61009-2-1

Product details

It is a 1P+N unit rated at 40 A with 300 mA sensitivity, Type AC, meaning it detects sinusoidal AC residual currents only — suitable for general-purpose socket-outlet and lighting circuits where no electronic loads with DC ripple are present. Rated operational voltage is 230 V AC phase-to-neutral at 50 Hz, with an insulation voltage of 400 V AC and impulse withstand of 6 kV per EN 61009-1. The device is voltage-independent — it trips on residual current alone, no external supply needed.

Certified to IEC 60947-2, EN 61009-1, and EN 61009-2-1. Operating temperature range -5 to 60 °C, storage -40 to 60 °C, with 95% relative humidity at 55 °C. Maximum operating altitude 2000 m.

Frequently asked questions

What is A9N21483's listed depth?

The A9N21483 has a depth of 70 mm.

What is A9N21483's listed range?

The A9N21483 belongs to the Prodis range.

What compliance documentation does this brand provide for A9N21483?

The A9N21483 is certified to IEC 60947-2, EN 61009-1, and EN 61009-2-1. It carries IP20 protection per IEC 60529 and tropicalisation class 2 per IEC 60068-1.

MPN