Schneider Electric A9N21496

Schneider Electric A9N21496 Vigi TG40 40A 30mA RCD, Obsolete

MPN A9N21496
Obsolete

Schneider Electric Prodis Vigi TG40 add-on residual current device, A9N21496, 3P+N, 40 A, 30 mA, Type A-SI, voltage-independent trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21496 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50 Hz phase to phase
Insulation voltage ui400 V AC 50 Hz conforming to EN 61009-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009-1
ColorWhite
Depth70 mm
Width54 mm
Height82 mm
Operating temperature-25...60 °C

Product details

The Schneider Electric A9N21496 is a Prodis Vigi TG40 add-on residual current device (RCD) — a voltage-independent earth-leakage block that clips onto the right side of a compatible MCB to provide 30 mA ground-fault protection. It is a 3P+N unit rated 40 A at 400 V AC phase-to-phase, with Type A-SI (Super Immunised) sensitivity that resists nuisance tripping from high-frequency harmonics or transient surges common on modern electronic loads. Mounts via clip-on to DIN rail, occupies 6 x 9 mm pitches (54 mm width), and connects to the upstream MCB by screws through the cable terminals (accepts 0.75–16 mm² rigid or 0.33–10 mm² flexible).

Lifecycle status and sourcing reality

The A9N21496 is marked obsolete by Schneider Electric.

40 A rated current (In) and 30 mA earth-leakage sensitivity make this a group-incomer or sub-distribution RCD for a 3-phase + neutral circuit feeding mixed loads. Voltage-independent trip technology means the RCD operates without needing a separate power supply; it uses the fault energy itself to open the contacts. Rated insulation voltage 400 V AC, impulse withstand 6 kV, pollution degree 3, and tropicalisation class 2 per IEC 60068-1. IP20 finger-safe terminals — intended for enclosed panel mounting, not washdown environments.

Designed and tested to IEC 60947-2, EN 61009-1, and EN 61009-2-1. The EN 61009 series covers residual current operated circuit-breakers with integral overcurrent protection — this add-on block is the RCD element intended to pair with a compatible MCB to form a complete RCBO assembly.