Schneider Electric A9N21563

A9N21563 Vigi TG60 4P 63A 300mA Earth Leakage Add-on Block

MPN A9N21563
Obsolete

Schneider Electric ProDis Vigi TG60 add-on residual current device, 4P, 63 A, 300 mA, Type AC, voltage independent, IP20, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21563 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage400 V AC 50 Hz phase to phase
Insulation voltage ui440 V AC 50 Hz conforming to EN 61009-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009-1
ColorWhite
Depth70 mm
Width54 mm
Height82 mm
Operating temperature-5...60 °C

Product details

It is a 4-pole unit rated 63 A with 300 mA sensitivity, Type AC (trips on sinusoidal AC residual currents), designed for group incomer duty in a distribution board. The clip-on mounting snaps onto a DIN rail alongside the paired MCB, making it a panel-integrated retrofit for an existing single-phase or three-phase subfeed.

Rated 63 A at 400 V AC phase-to-phase, 50 Hz. The 300 mA sensitivity is an equipment-protection threshold. Voltage-independent tripping means the RCD does not need a separate power supply to operate — it derives its trip energy from the fault current itself. This makes it inherently fail-safe against loss of neutral or supply voltage, a common requirement in industrial and commercial distribution where a powered RCD might not trip during a broken-neutral fault. Instantaneous time delay means it trips within the standard fast-response window (typically under 40 ms at 5× IΔn) — no intentional delay for selectivity. If you need coordination with downstream RCDs, a time-delayed (S-type) device is the correct choice. Pollution degree 3 and IP20 confirm it is intended for a clean, dry enclosure — not for washdown or outdoor mounting without a weatherproof cabinet.

Clip-on mounting on DIN rail. The add-on block screws directly to the side of the paired MCB. Cable terminals accept 0.75…16 mm² rigid or 0.33…10 mm² flexible.