Schneider Electric A9N21566 iDPN N MCB, 10 A, D Curve, 1P+N

MPNA9N21566
Obsolete

Schneider Electric Clario iDPN N miniature circuit breaker, A9N21566, 10 A rated current, D tripping curve, 1P+N, 6 kA breaking capacity at 230 V AC, thermal-magnetic trip unit, DIN rail clip-on.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N21566 — Identification
ParameterValue
Product nameIDPN
Product / component typeMiniature circuit-breaker
Product rangeClario
Device short nameiDPN N
Poles description1P + N
Number of protected poles1
Device applicationDistribution
A9N21566 — Electrical & Protection
ParameterValue
Rated current (In)10 A
Rated operational voltage (Ue)230 V AC 50/60 Hz between phase and neutral
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu / AIR)6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N21566 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals downstream 0.33...10 mm² flexible Tunnel type terminals downstream 0.75...16 mm² rigid Tunnel type terminals upstream 0.33...10 mm² flexible Tunnel type terminals upstream 0.75...16 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width18 mm
Height81 mm
Depth78 mm
Tightening torque (by circuit)2 N.m
A9N21566 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20 conforming to IEC 60529
A9N21566 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1
A9N21566 — Electrical
ParameterValue
[Ui] rated insulation voltage400 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60947-2

Product details

It protects a single pole plus neutral (1P+N) in AC distribution circuits at 50/60 Hz. Breaking capacity is 6000 A Icn at 230 V AC, certified to EN/IEC 60898-1.

Depth is 78 mm, height 81 mm. IP20 finger-safe terminals; the breaker is intended for enclosed distribution boards, not open-panel washdown areas. Tightening torque 2 N.m, strip length 13 mm. The toggle gives local ON/OFF indication. Earth-leakage protection requires a separate block — not integrated.

No direct pin-compatible alternative exists within the same iDPN N range at this rating and curve — the D-curve 10 A 1P+N is the only variant at these parameters.

Durability and environmental ratings

Electrical and mechanical durability both rated at 20,000 cycles. Suitable for isolation (full disconnection on the protected pole).

Frequently asked questions

Where can I buy the A9N21566 and get a price?

The A9N21566 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is the breaking capacity of the A9N21566?

The breaking capacity is 6000 A Icn at 230 V AC, 50/60 Hz, certified to EN/IEC 60898-1.

What compliance documentation does Schneider provide for the A9N21566?

The breaker is certified to EN/IEC 60898-1 and IEC 60947-1 (pollution degree 3). Tropicalisation per IEC 60068-1 class 2. Standard Schneider documentation includes the declaration of conformity and CE marking; RoHS and REACH compliance are covered by the brand's general material declarations.