Schneider Electric Clario Vigi DPNc add-on residual current device, 3P+N, 40 A rated current, 300 mA sensitivity, Type AC, voltage independent, obsolete lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N21758 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationON/OFF indication
A9N21758 — Electrical Ratings
ParameterValue
Rated current (In)40 A
Rated operational voltage (Ue)400 V AC 50 Hz phase to phase
Poles description3P + N
Neutral pole positionLeft
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)440 V AC 50 Hz conforming to EN/IEC 61009-1
Rated impulse withstand voltage (Uimp)4 kV conforming to EN/IEC 61009-1
Device location in systemGroup incomer
A9N21758 — Identification
ParameterValue
Product / component typeAdd-on residual current device
Product range / familyClario
Device short nameVigi DPNc
A9N21758 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules6
Terminal connectionsCable upstream 0.75...16 mm² rigid Cable upstream 0.33...10 mm² flexible
Wire stripping length13 mm
Terminal tightening torque2 N.m
Width54 mm
Height82 mm
Depth70 mm
A9N21758 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...60 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 61009-1
Relative humidity95 % at 55 °C
Operating altitude2000 m
Tropicalisation2 conforming to IEC 60068-1
A9N21758 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

The A9N21758: This is an add-on residual current device (RCD) — the Vigi DPNc — designed to clip onto the side of a compatible MCB (the DPNc series) to provide earth-leakage protection in a single module width. It is not a standalone RCBO; it requires a mechanical and electrical connection to the matching MCB via the screw terminals. The 40 A rated current and 300 mA sensitivity make it a group-incomer device — typically installed at the head of a sub-distribution board to protect multiple downstream circuits against earth faults, not for individual final-circuit protection where 30 mA is standard. The impulse withstand voltage is 4 kV, conforming to EN/IEC 61009-1 — this is the standard for residual current operated circuit breakers with integral overcurrent protection, though this unit is the add-on block only. The voltage-independent tripping technology means the RCD will trip on residual current even if the phase voltage is lost — a safety advantage in fault conditions where the neutral may remain live.

Mounts via clip-on to a DIN rail — standard 35 mm symmetrical rail. The 3P+N poles description with neutral on the left means it occupies four module positions (9 mm pitches each, 6 total per the spec, so 54 mm width). Depth is 70 mm, height 82 mm.

Relative humidity tolerance is 95% at 55 °C. Maximum operating altitude is 2000 m. Standards compliance includes EN/IEC 61009-1 and EN/IEC 61009-2-1.

Frequently asked questions

How do I get current pricing and availability for A9N21758?

Submit an RFQ through this listing. Since the part is obsolete, availability and pricing are confirmed at quote time through our independent sourcing network. No stock figures or prices are listed here because they change with each procurement cycle.

What are the key ratings for A9N21758?

Rated current 40 A, earth-leakage sensitivity 300 mA Type AC, rated operational voltage 400 V AC phase-to-phase, insulation voltage 440 V AC, impulse withstand 4 kV, voltage-independent tripping.