Schneider Electric A9N2P03CGN Acti9 xC60 MCB, 3A C-curve 2P

MPNA9N2P03CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P03CGN, 3A rated current, C-curve, 2-pole, 10kA breaking capacity, 35mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P03CGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P03CGN — Electrical
ParameterValue
Rated current [In]3 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P03CGN — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P03CGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P03CGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P03CGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

The Schneider Electric A9N2P03CGN is an Acti9 xC60 miniature circuit breaker — a 3 A, C-curve, 2-pole unit rated for 10 kA breaking capacity at 240 V AC and 415 V AC per IS/IEC 60898-1. Thermal-magnetic trip, toggle control, clip-on mount to 35 mm DIN rail.

Snaps onto a 35 mm DIN rail in the distribution board — 36 mm width (4 x 9 mm pitches), 85 mm height, 77.5 mm depth. Tightening torque 2 N·m. IP20 finger-safe front, pollution degree 3, overvoltage category IV — standard for main distribution panels.

C-curve magnetic trip threshold is 5 to 10 times In (15 to 30 A), so it's sized for inductive loads like small motors or lighting banks where inrush is moderate. Rated for 20,000 electrical and 20,000 mechanical cycles. Earth-leakage protection requires a separate block — this is the MCB only.

Frequently asked questions

What is the breaking capacity of A9N2P03CGN?

10,000 A Icn at both 240 V AC and 415 V AC, 50/60 Hz, conforming to IS/IEC 60898-1.

What is the rated current and curve of A9N2P03CGN?

3 A rated current, C-curve (magnetic trip 5 to 10 x In).

Where can I buy A9N2P03CGN?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN