Schneider Electric A9N2P10BGN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P10BGN Acti9 xC60 MCB, 10A B-Curve 2P

MPNA9N2P10BGN
Active

Schneider Electric Acti9 xC60, miniature circuit-breaker, A9N2P10BGN, 10 A, B-curve, 2P, 10 kA Icn at 240/415 V AC, IS/IEC 60898-1.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P10BGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P10BGN — Electrical
ParameterValue
Rated current [In]10 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P10BGN — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit3...5 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P10BGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P10BGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P10BGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

What it is and where it fits

The Schneider Electric A9N2P10BGN is a 2-pole miniature circuit-breaker from the Acti9 xC60 series, rated 10 A with a B-curve trip characteristic. It clips onto a 35 mm DIN rail and occupies 4 x 9 mm pitches — 36 mm wide — so it slots into a standard distribution board alongside other Acti9 modules. The thermal-magnetic trip unit handles overloads and short-circuits; the B-curve means magnetic tripping occurs at 3 to 5 times rated current, making it the right choice for resistive or general-purpose loads where inrush is low — lighting circuits, socket outlets, small control transformers.

Breaking capacity and standards

Breaking capacity is 10,000 A Icn at both 240 V and 415 V AC, 50/60 Hz, certified to IS/IEC 60898-1. That 10 kA rating at 415 V is the figure that governs selectivity in a three-phase distribution panel — it tells you the breaker can safely interrupt a fault up to that level without upstream devices needing to clear it. Pollution degree 3 and overvoltage category IV mean it's rated for the harsh electrical environment of a main distribution board, not just a clean sub-panel.

Integration notes

Clip-on mounting to 35 mm DIN rail — no tools needed for installation. Terminals accept up to 25 mm² rigid or 16 mm² flexible; strip length 13 mm. Tightening torque 2 N.m. The white housing with toggle control and ON/OFF indication gives clear visual status. IP20 means it's protected against finger contact but not washdown — keep it inside the enclosure.

Frequently asked questions

What is the breaking capacity of A9N2P10BGN?

The A9N2P10BGN has a breaking capacity of 10,000 A Icn at both 240 V and 415 V AC, 50/60 Hz, per IS/IEC 60898-1.

Where can I buy A9N2P10BGN?

The A9N2P10BGN is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the depth of A9N2P10BGN?

The A9N2P10BGN has a depth of 77.5 mm.

What range does A9N2P10BGN belong to?

The A9N2P10BGN belongs to the Schneider Electric Acti9 range.