Skip to main content
Schneider Electric A9N2P16DGN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P16DGN Acti9 xC60 MCB, 16 A, D Curve,

MPNA9N2P16DGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P16DGN, 2-pole, 16 A, D curve, 10 kA breaking capacity, 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P16DGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P16DGN — Electrical
ParameterValue
Rated current [In]16 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P16DGN — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit10...14 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P16DGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P16DGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P16DGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

The Schneider Electric A9N2P16DGN is a 2-pole miniature circuit breaker from the Acti9 xC60 range, rated 16 A with a D tripping curve and a breaking capacity of 10 kA at 240 V AC and also at 415 V AC per IS/IEC 60898-1. Rated operational voltage covers 220–240 V AC and 380–415 V AC at 50/60 Hz, so it handles standard single-phase and three-phase distribution panels. The thermal-magnetic trip unit gives you both overload protection (thermal bimetal) and short-circuit protection (magnetic coil) in one package.

Clip-on mounting on a 35 mm DIN rail, 36 mm wide (2 module spaces at 9 mm pitch = 4 pitches). Depth is 77.5 mm, height 85 mm — standard for the Acti9 family, so it slots into existing distribution boards without re-spacing.

The 20,000 electrical and 20,000 mechanical cycles give a solid service life for normal switching duty. Earth-leakage protection requires a separate block (not integrated), so if you need RCD functionality, add a compatible Acti9 vigi module downstream. The toggle switch gives local ON/OFF indication — useful for troubleshooting without a meter.

Frequently asked questions

What are the key specifications of A9N2P16DGN?

It is a 2-pole miniature circuit breaker, 16 A rated current, D curve (magnetic trip 10–14 x In), breaking capacity 10 kA at 240 V AC and 415 V AC per IS/IEC 60898-1. Mounts on 35 mm DIN rail, 36 mm wide, 77.5 mm deep.

Where can I buy A9N2P16DGN?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm offer.

What standards does A9N2P16DGN comply with?

It complies with IS/IEC 60898-1, the standard for miniature circuit breakers for overcurrent protection. Pollution degree 3 and overvoltage category IV are specified for industrial environments.

MPN
A9N2P16DGN