Skip to main content
Schneider Electric A9N2P16DIN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P16DIN Acti9 xC60 MCB, 16 A, D Curve,

MPNA9N2P16DIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P16DIN, 16 A rated, D curve, 2-pole, 10 kA breaking capacity at 415 V AC, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P16DIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P16DIN — Electrical
ParameterValue
Rated current [In]16 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9N2P16DIN — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity [Ics]6 kA conforming to IS/IEC 60947-2 - 100...125 V DC 7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz
Energy limitation class3 conforming to IS/IEC 60947-2
Suitable for isolationYes conforming to IS/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P16DIN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P16DIN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P16DIN — Approvals
ParameterValue
Standards / complianceIS/IEC 60947-2

Product details

The Schneider Electric A9N2P16DIN is an Acti9 xC60 miniature circuit breaker rated at 16 A with a D tripping curve, meaning its magnetic trip threshold sits at 12 x In ±20 % — designed for loads with high inrush, like motor circuits or transformers, where the start-up surge would nuisance-trip a B or C curve. Breaking capacity is 10 kA Icn at 380–415 V AC 50/60 Hz per IS/IEC 60947-2, with a 6 kA Icu at 100–125 V DC for DC circuits. The 2-pole unit clips onto a 35 mm DIN rail, occupies 4 x 9 mm pitches (36 mm wide), and stands 85 mm tall with a 77.5 mm depth — fits standard distribution boards with room for gland plates and wiring ducts.

Integration notes

Clip-on mounting on 35 mm DIN rail — no screws needed, snaps into place and releases with a screwdriver slot.

Frequently asked questions

What is A9N2P16DIN's listed depth?

The A9N2P16DIN has a depth of 77.5 mm, fitting standard distribution board depths.

What is A9N2P16DIN's listed range?

The A9N2P16DIN belongs to the Schneider Electric Acti9 range, specifically the xC60 series of miniature circuit breakers.

What compliance documentation does this brand provide for A9N2P16DIN?

The A9N2P16DIN is certified to IS/IEC 60947-2, with tropicalisation class 2 per IEC 60068-1 and limitation class 3 per IS/IEC 60947-2.

MPN
A9N2P16DIN