Schneider Electric A9N2P20BIN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P20BIN Acti9 xC60 MCB, 20 A, B Curve,

MPNA9N2P20BIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P20BIN, 20 A, B curve, 2-pole, 10 kA breaking capacity at 415 V AC, clip-on DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P20BIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P20BIN — Electrical
ParameterValue
Rated current [In]20 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Network type (AC/DC)DC AC
Network frequency50/60 Hz
A9N2P20BIN — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit4 x In +/- 20 %
Breaking capacity (Icu)10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity [Ics]6 kA conforming to IS/IEC 60947-2 - 100...125 V DC 7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz
Energy limitation class3 conforming to IS/IEC 60947-2
Suitable for isolationYes conforming to IS/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P20BIN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P20BIN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P20BIN — Approvals
ParameterValue
Standards / complianceIS/IEC 60947-2

Product details

The Schneider Electric A9N2P20BIN is an Acti9 xC60 miniature circuit breaker rated 20 A with a B tripping curve, 2-pole configuration, and a breaking capacity of 10 kA Inc at 380–415 V AC 50/60 Hz per IS/IEC 60947-2.

Depth 77.5 mm, height 85 mm. That 36 mm footprint for a 2-pole MCB is standard — it occupies two module positions on the rail, so a 12-module enclosure holds six of these side by side. Tightening torque 2 N·m.

The 6 kA Icu at 100–125 V DC covers DC-side protection for battery banks or DC busbars.

Certified to IS/IEC 60947-2, Category A — the standard for MCBs used in distribution. Limitation class 3 per that standard, meaning it limits let-through energy well. IP20 finger-safe terminals. Earth-leakage protection via a separate block if needed. The brand provides standard compliance documentation (RoHS, REACH, CE, UKCA) with the product; specific declarations available on request.

Frequently asked questions

What is the breaking capacity of A9N2P20BIN?

10 kA Inc at 380–415 V AC 50/60 Hz per IS/IEC 60947-2, and 6 kA Icu at 100–125 V DC.

What is the closest alternative to A9N2P20BIN in the Acti9 family?

Within the same Acti9 xC60 range, the closest alternative would be a different current rating or curve — for example, a 20 A C-curve variant (A9N2P20CIN) if the load has higher inrush. The physical footprint (36 mm, 2-pole) and breaking capacity are identical; only the magnetic trip threshold changes.

Where can I buy A9N2P20BIN?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response.

MPN
A9N2P20BIN