Schneider Electric A9N2P20CGN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P20CGN Acti9 xC60 MCB, 20A, 2P, C-Cur

MPNA9N2P20CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P20CGN, 2-pole, 20 A rated current, C-curve, 10 kA breaking capacity, clip-on 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P20CGN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P20CGN — Electrical
ParameterValue
Rated current [In]20 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
A9N2P20CGN — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu)10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
Energy limitation class3 conforming to IS/IEC 60898-1
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P20CGN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)
Terminal tightening torque2 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P20CGN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P20CGN — Approvals
ParameterValue
Standards / complianceIS/IEC 60898-1

Product details

The Schneider Electric A9N2P20CGN is a 2-pole miniature circuit breaker from the Acti9 xC60 range, rated 20 A with a C-curve trip characteristic. The C-curve means the magnetic trip operates between 5 and 10 times the rated current — so for a 20 A breaker, instantaneous trip occurs between 100 A and 200 A. That makes it a good fit for general-purpose loads like lighting, socket outlets, and small appliances where inrush is moderate. Breaking capacity is 10 kA Icn at both 240 V and 415 V AC, certified to IS/IEC 60898-1.

Depth is 77.5 mm, height 85 mm — standard footprint for a 2P MCB in the Acti9 family, so it swaps into an existing board without re-drilling the backplate. The bottom terminals also support a biconnect feature for daisy-chaining or looping out to the next device.

The A9N2P20CGN is listed as current-production (active lifecycle stage). No end-of-life notice or last-time-buy date is available for this order code.

Certified to IS/IEC 60898-1, the Indian-standard version of the IEC 60898-1 for AC miniature circuit breakers. Pollution degree 3, overvoltage category IV — suitable for main distribution boards where the breaker sees the full utility fault level. Tropicalisation level 2 per IEC 60068-1 means it withstands damp heat — relevant for coastal or high-humidity installations. Relative humidity rating is 95 % at 55 °C. Electrical and mechanical durability both rated at 20,000 cycles — typical for a distribution MCB; not a switching device for frequent motor starts.