Skip to main content
Schneider Electric A9N2P32DGN

Schneider Electric A9N2P32DGN Acti9 xC60 MCB, D Curve, 32 A,

MPN A9N2P32DGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P32DGN, D curve, 32 A, 2-pole, 10 kA breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N2P32DGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1 10000 A Icn at 415 V AC 50/60 Hz conforming to IS/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9N2P32DGN additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N2P32DGN is a 2-pole miniature circuit breaker from the Acti9 xC60 range, rated 32 A with a D tripping curve. It clips onto a standard 35 mm DIN rail (4 module pitches, 36 mm wide) and fits distribution boards or subpanels where the 10 kA breaking capacity at 240 V AC (also 10 kA at 415 V AC) covers most commercial and light industrial fault levels.

The 32 A continuous rating and D-curve magnetic threshold make this a go-to for motor branch circuits and transformer primary protection where the inrush lasts several cycles. The 10 kA Icn at both 240 V and 415 V AC (per IS/IEC 60898-1) is the short-circuit capacity the breaker can safely interrupt — enough for most panelboards fed from a 200 kVA or smaller transformer. Thermal-magnetic trip technology handles overloads (thermal bimetal) and short-circuits (solenoid) in one package.

DIN-rail integration notes

Tightening torque 3.5 N·m. The toggle gives local ON/OFF indication. IP20 finger-safe terminals — fine inside an enclosed panel, not for wet locations.

MPN