Skip to main content
Schneider Electric A9N2P32DIN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P32DIN Acti9 xC60 MCB, 32 A, D Curve,

MPNA9N2P32DIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P32DIN, 2-pole, 32 A rated current, D curve, 10 kA breaking capacity at 415 V AC, clip-on 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P32DIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P32DIN — Electrical
ParameterValue
Rated current [In]32 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9N2P32DIN — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity [Ics]6 kA conforming to IS/IEC 60947-2 - 100...125 V DC 7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz
Energy limitation class3 conforming to IS/IEC 60947-2
Suitable for isolationYes conforming to IS/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P32DIN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P32DIN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P32DIN — Approvals
ParameterValue
Standards / complianceIS/IEC 60947-2

Product details

The Schneider Electric A9N2P32DIN is a 2-pole miniature circuit breaker from the Acti9 xC60 range, rated 32 A with a D tripping curve.

Breaking capacity is 10 kA Icn at 380–415 V AC 50/60 Hz per IS/IEC 60947-2, with a 6 kA Icu at 100–125 V DC. The D curve and 10 kA rating allow this breaker to sit downstream of a larger upstream device (e.g., a 25 kA or 36 kA Compact NSX) and still achieve full selectivity under fault — the 12 × In magnetic hold keeps the downstream breaker from tripping ahead of the upstream one on a high-impedance fault.

The 9 mm pitch (4 pitches wide) matches standard DIN-rail terminal blocks, so the breaker occupies the same footprint as a 36 mm wide accessory — no extra panel space needed for the wiring gland.

Frequently asked questions

What is the breaking capacity of A9N2P32DIN?

10 kA Icn at 380–415 V AC 50/60 Hz per IS/IEC 60947-2, and 6 kA Icu at 100–125 V DC. The D curve magnetic trip is 12 × In ±20 %.

Where can I buy A9N2P32DIN?

We source the A9N2P32DIN to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution network.

What is the closest alternative to A9N2P32DIN in the Acti9 range?

Within the same Acti9 xC60 family, the closest alternative is a 2-pole D-curve breaker at a different current rating — for example, the 25 A or 40 A variant. The physical footprint, terminal capacity, and breaking capacity are identical; only the thermal-magnetic calibration changes. No pin-compatible substitute exists outside the Acti9 platform.

MPN
A9N2P32DIN