Schneider Electric A9N2P40CIN — 2-Pole MCB (DIN Rail)

Schneider Electric A9N2P40CIN Acti9 xC60 MCB, 40 A, C-Curve,

MPNA9N2P40CIN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, A9N2P40CIN, 40 A, C-curve, 2-pole, 10 kA breaking capacity, clip-on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9N2P40CIN — Identification
ParameterValue
Product nameXC60
Product rangeActi9
Series / familyActi9
Device short namexC60
Product / component typeMiniature circuit-breaker
Device applicationDistribution
A9N2P40CIN — Electrical
ParameterValue
Rated current [In]40 A
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Network type (AC/DC)AC DC
Network frequency50/60 Hz
A9N2P40CIN — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8 x In +/- 20 %
Breaking capacity (Icu)10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Rated service breaking capacity [Ics]6 kA conforming to IS/IEC 60947-2 - 100...125 V DC 7.5 kA conforming to IS/IEC 60947-2 - 380...415 V AC 50/60 Hz
Energy limitation class3 conforming to IS/IEC 60947-2
Suitable for isolationYes conforming to IS/IEC 60947-2
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
A9N2P40CIN — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height85 mm
Depth77.5 mm
Mounting support35 mm DIN rail
Mounting modeClip-on
Terminal connectionsBiconnect (bottom) Tunnel type terminals (bottom) 25 mm² flexible Tunnel type terminals (bottom) 35 mm² rigid
Terminal tightening torque3.5 N.m
Comb busbar / distribution block compatibilityTop: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
A9N2P40CIN — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
A9N2P40CIN — Approvals
ParameterValue
Standards / complianceIS/IEC 60947-2

Product details

The Schneider Electric A9N2P40CIN is a 40 A, C-curve, 2-pole miniature circuit breaker from the Acti9 xC60 series. The thermal-magnetic trip unit gives you a magnetic tripping limit of 8 x In ±20% — meaning the magnetic coil picks up around 320 A for a fast short-circuit break.

Breaking capacity — what the 10 kA rating means in practice

The A9N2P40CIN carries a breaking capacity of 10 kA Icn at 380–415 V AC, certified to IS/IEC 60947-2. On the DC side it's rated 6 kA Icu at 100–125 V DC. Below that, on downstream sub-circuits, it has headroom.

Where it fits — panel integration and environment

The breaker occupies 36 mm width (4 x 9 mm pitches) on a 35 mm DIN rail, with a depth of 77.5 mm and height of 85 mm. That's a standard 2-module footprint — it leaves room for a separate earth-leakage block downstream if you need RCD protection. The clip-on mounting means no screws or tools to install it; just snap it onto the rail and wire it. Pollution degree 3 means it's tested for conductive dust and occasional condensation, typical of industrial control rooms and factory floors.

Frequently asked questions

Where can I buy the A9N2P40CIN and get a price?

The A9N2P40CIN is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of the A9N2P40CIN?

The A9N2P40CIN has a breaking capacity of 10 kA Icn at 380–415 V AC and 6 kA Icu at 100–125 V DC, certified to IS/IEC 60947-2.

What does the C-curve mean on this breaker?

The C-curve means the magnetic trip operates at 8 x In ±20% — around 320 A for this 40 A breaker. It's the standard choice for general-purpose loads like lighting, socket circuits, and small motors where you need to ride through inrush without nuisance tripping.

MPN