Skip to main content
Schneider Electric A9N2P40CIN

Schneider Electric A9N2P40CIN Acti9 xC60 MCB, 40 A, C-Curve,

MPN A9N2P40CIN
Active

Schneider Electric Acti9 xC60, miniature circuit breaker, A9N2P40CIN, 40 A, C-curve, 2-pole, 10 kA breaking capacity, clip-on 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N2P40CIN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C

All specifications

A9N2P40CIN additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N2P40CIN is a 40 A, C-curve, 2-pole miniature circuit breaker from the Acti9 xC60 series. The thermal-magnetic trip unit gives you a magnetic tripping limit of 8 x In ±20% — meaning the magnetic coil picks up around 320 A for a fast short-circuit break.

Breaking capacity — what the 10 kA rating means in practice

The A9N2P40CIN carries a breaking capacity of 10 kA Icn at 380–415 V AC, certified to IS/IEC 60947-2. On the DC side it's rated 6 kA Icu at 100–125 V DC. Below that, on downstream sub-circuits, it has headroom.

Where it fits — panel integration and environment

The breaker occupies 36 mm width (4 x 9 mm pitches) on a 35 mm DIN rail, with a depth of 77.5 mm and height of 85 mm. That's a standard 2-module footprint — it leaves room for a separate earth-leakage block downstream if you need RCD protection. The clip-on mounting means no screws or tools to install it; just snap it onto the rail and wire it. Pollution degree 3 means it's tested for conductive dust and occasional condensation, typical of industrial control rooms and factory floors.

MPN
A9N2P40CIN